Confidence-Based Rejection for Improved Pattern Recognition Myoelectric Control
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study describes a novel myoelectric control scheme that is capable of motion rejection. As an extension of the commonly used linear discriminant analysis (LDA), this system generates a confidence score for each decision, providing the ability to reject those with a score below a selected threshold. The thresholds are class-specific and affect only the rejection characteristics of the associated class. Furthermore, because the rejection stage is implemented using the outputs of the LDA, the active motion classification accuracy of the proposed system is shown to outperform that of the LDA for all values of rejection threshold. The proposed scheme was compared to a baseline LDA-based pattern recognition system using a real-time Fitts' law-based target acquisition task. The use of velocity-based myoelectric control using the rejection classifier is shown to obey Fitts' law, producing linear regression fittings with high coefficients of determination (R(2) > 0.943). Significantly higher (p < 0.001) throughput, path efficiency, and completion rates were observed with the rejection-capable system for both able-bodied and amputee subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 1×
“Fitts’ law testing uses a single throughput (TP) statistic to represent the results from repeated trials and is measured in bits per second [27].”
MethodA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citation
Cited by
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“Further, towards improving the classification performance, robustness, and usability of EMG-PR systems, as well as to overcome the limitations of the conventional EMG control methods, postprocessing strategies such Majority Voting [63], Bayesian Fusion (BF) [64], self-correcting schemes and rejectionbased methods have…”
MethodBetthauser, J. L., Krall, J. T., Bannowsky, S. G., Levay, G., Kaliki, R. R., Fifer, M. S., & Thakor, N. V. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2943309 · Cited by 73
Recording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
Metadata
- Authors
- Scheme, E. J., Hudgins, B. S., & Englehart, K. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-06
- Volume
- 60
- Issue
- 6
- Pages
- 1563-1570
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2170128511
- Cited by
- 136
- References
- 2
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.