Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Stable Responsive EMG Sequence Prediction and Adaptive Reinforcement With Temporal Convolutional Networks

Open access
Betthauser, Joseph L., Krall, John T., Bannowsky, Shain G., Levay, Gyorgy, Kaliki, Rahul R., Fifer, Matthew S., Thakor, Nitish V. · 2020 · IEEE Transactions on Biomedical Engineering

Abstract

Prediction of movement intentions from electromyographic (EMG) signals is typically performed with a pattern recognition approach, wherein a short dataframe of raw EMG is compressed into an instantaneous feature-encoding that is meaningful for classification. However, EMG signals are time-varying, implying that a frame-wise approach may not sufficiently incorporate temporal context into predictions, leading to erratic and unstable prediction behavior. OBJECTIVE: We demonstrate that sequential prediction models and, specifically, temporal convolutional networks are able to leverage useful temporal information from EMG to achieve superior predictive performance. METHODS: We compare this approach to other sequential and frame-wise models predicting 3 simultaneous hand and wrist degrees-of-freedom from 2 amputee and 13 non-amputee human subjects in a minimally constrained experiment. We also compare these models on the publicly available Ninapro and CapgMyo amputee and non-amputee datasets. RESULTS: Temporal convolutional networks yield predictions that are more accurate and stable than frame-wise models, especially during inter-class transitions, with an average response delay of 4.6 ms and simpler feature-encoding. Their performance can be further improved with adaptive reinforcement training. SIGNIFICANCE: Sequential models that incorporate temporal information from EMG achieve superior movement prediction performance and these models allow for novel types of interactive training. CONCLUSIONS: Addressing EMG decoding as a sequential modeling problem will lead to enhancements in the reliability, responsiveness, and movement complexity available from prosthesis control systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2019.2943309

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Research works printed but not linked: 1

  1. ravitz, 2013, Revolutionizing prosthetics–Phase 3, Johns Hopkins APL Tech Dig, 31, 366

Cited by

See all 73

Metadata

Authors
Betthauser, J. L., Krall, J. T., Bannowsky, S. G., Levay, G., Kaliki, R. R., Fifer, M. S., & Thakor, N. V.
Affiliations
  • Johns Hopkins University (US)
  • Infinite Biomedical Technologies (United States) (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
2020-06
Volume
67
Issue
6
Pages
1707-1717
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2977057839
Cited by
73
References
46
Citations by year
2026: 4 · 2025: 18 · 2024: 9 · 2023: 13 · 2022: 14 · 2021: 13 · 2020: 2
FWCI
2.55
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
Johns Hopkins University Applied Physics Laboratory Graduate Research Fellowship
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
electromyography, temporal convolutional network, adaptive reinforcement learning, response latency, Ninapro dataset, temporal context
MeSH terms
Amputees, Artificial Limbs, Electromyography, Hand, Humans, Movement, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stable Responsive EMG Sequence Prediction and Adaptive Reinforcement With Temporal Convolutional Networks. https://app.cochat.ai/papers/10.1109/tbme.2019.2943309
The paper
Betthauser, J. L., Krall, J. T., Bannowsky, S. G., Levay, G., Kaliki, R. R., Fifer, M. S., & Thakor, N. V. (2020). Stable Responsive EMG Sequence Prediction and Adaptive Reinforcement With Temporal Convolutional Networks. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2019.2943309

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.