SSVEP-Based Brain–Computer Interfaces Using FSK-Modulated Visual Stimuli
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) based on steady-state visual-evoked potentials (SSVEP) has two difficulties: limitation of the number of commands and uneven probabilities of command execution. To address these problems, the present paper proposes a paradigm of BCI using frequency-modulated visual stimuli. The commands are translated into code words consisting of binary digits, to which visual stimuli with distinct frequencies are assigned. Frequencies of SSVEP are recognized to detect bits, and a command to be executed is determined from the sequence of detected bits. Experimental results show that the proposed paradigm achieves a reliable BCI with higher accuracies and balanced command executing probabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“For noninvasive BCIs, the EEG is widely used because of the small size of equipment (compared to functional magnetic resonance imaging, magnetoencephalography, and so forth) and high time resolution [2], [3].”
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 1×
“However, since the earlier works, several authors have reported SSVEP elicited from stimuli with a frequency below 3 Hz [11]–[14], and up to 80 Hz (gamma frequency band) [12], [15], [16].”
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
A Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
Towards a cure for BCI illiteracy
Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
Steady-state evoked potentials
Regan, D. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001475 · Cited by 266 · cited 1×
“2265260 SSVEP [9], [10] reported a narrow range of effective flickering frequencies of from 6 to 30 Hz.”
Cited by
Enhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
EEG source imaging enhances the decoding of complex right-hand motor imagery tasks
Edelman, B. J., Baxter, B., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2467312 · Cited by 370
“such as the P300 [4]–[6], steady-state visual evoked potentials [7]–[9], slow cortical potentials [10], and sensorimotor rhythms (SMRs) [11], [12].”
BackgroundNakanishi, M., Wang, Y., Wang, Y.-T., & Jung, T.-P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140703 · Cited by 376
“For example, sequential encoding approaches such as the multiple frequencies sequential coding (MFSC) [7] and the frequency shift keying (FSK) [8] methods have been employed to increase the number of BCI commands using the limited number of available frequencies.”
MethodA HIGH-SPEED BRAIN SPELLER USING STEADY-STATE VISUAL EVOKED POTENTIALS
NAKANISHI, M., WANG, Y., WANG, Y.-T., MITSUKURA, Y., & JUNG, T.-P. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500191 · Cited by 369
Metadata
- Authors
- Kimura, Y., Tanaka, T., Higashi, H., & Morikawa, N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 2831-2838
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2089565727
- Cited by
- 75
- References
- 8
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.