The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Augmented Reality Navigation With Automatic Marker-Free Image Registration Using 3-D Image Overlay for Dental Surgery
Abstract
Computer-assisted oral and maxillofacial surgery (OMS) has been rapidly evolving since the last decade. State-of-the-art surgical navigation in OMS still suffers from bulky tracking sensors, troublesome image registration procedures, patient movement, loss of depth perception in visual guidance, and low navigation accuracy. We present an augmented reality navigation system with automatic marker-free image registration using 3-D image overlay and stereo tracking for dental surgery. A customized stereo camera is designed to track both the patient and instrument. Image registration is performed by patient tracking and real-time 3-D contour matching, without requiring any fiducial and reference markers. Real-time autostereoscopic 3-D imaging is implemented with the help of a consumer-level graphics processing unit. The resulting 3-D image of the patient's anatomy is overlaid on the surgical site by a half-silvered mirror using image registration and IP-camera registration to guide the surgeon by exposing hidden critical structures. The 3-D image of the surgical instrument is also overlaid over the real one for an augmented display. The 3-D images present both stereo and motion parallax from which depth perception can be obtained. Experiments were performed to evaluate various aspects of the system; the overall image overlay error of the proposed system was 0.71 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Cited by
Augmented reality in neurosurgery: a systematic review
Meola, A., Cutolo, F., Carbone, M., Cagnazzo, F., Ferrari, M., & Ferrari, V. (2017) · Neurosurgical Review · doi:10.1007/s10143-016-0732-9 · Cited by 349
Lungu, A. J., Swinkels, W., Claesen, L., Tu, P., Egger, J., & Chen, X. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1860750 · Cited by 269
Application of artificial intelligence in surgery
Zhou, X.-Y., Guo, Y., Shen, M., & Yang, G.-Z. (2020) · Frontiers of Medicine · doi:10.1007/s11684-020-0770-0 · Cited by 181
Ibrahim, Z., & Money, A. G. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103102 · Cited by 26
Metadata
- Authors
- Wang, J., Suenaga, H., Hoshi, K., Yang, L., Kobayashi, E., Sakuma, I., & Liao, H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-04
- Volume
- 61
- Issue
- 4
- Pages
- 1295-1304
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2041859616
- Cited by
- 209
- References
- 1
- FWCI
- 14.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.