A Noncontact Capacitive Sensing System for Recognizing Locomotion Modes of Transtibial Amputees
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a noncontact capacitive sensing system (C-Sens) for locomotion mode recognition of transtibial amputees. C-Sens detects changes in physical distance between the residual limb and the prosthesis. The sensing front ends are built into the prosthetic socket without contacting the skin. This novel signal source improves the usability of locomotion mode recognition systems based on electromyography (EMG) signals and systems based on capacitance signals obtained from skin contact. To evaluate the performance of C-Sens, we carried out experiments among six transtibial amputees with varying levels of amputation when they engaged in six common locomotive activities. The capacitance signals were consistent and stereotypical for different locomotion modes. Importantly, we were able to obtain sufficiently informative signals even for amputees with severe muscle atrophy (i.e., amputees lacking of quality EMG from shank muscles for mode classification). With phase-dependent quadratic classifier and selected feature set, the proposed system was capable of making continuous judgments about locomotion modes with an average accuracy of 96.3% and 94.8% for swing phase and stance phase, respectively (Experiment 1). Furthermore, the system was able to achieve satisfactory recognition performance after the subjects redonned the socket (Experiment 2). We also validated that C-Sens was robust to load bearing changes when amputees carried 5-kg weights during activities (Experiment 3). These results suggest that noncontact capacitive sensing is capable of circumventing practical problems of EMG systems without sacrificing performance and it is, thus, promising for automatic recognition of human motion intent for controlling powered prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 3×
“0% in the stance phase and swing phase, respectively [13].”
BackgroundResultInfluentialLower Limb Wearable Capacitive Sensing and Its Applications to Recognizing Human Gaits
Zheng, E., Chen, B., Wei, K., & Wang, Q. (2013) · Sensors · doi:10.3390/s131013334 · Cited by 26 · cited 4×
“disadvantages, we proposed to use capacitive sensing as an alternative to EMG sensing for mode recognition [22]–[24].”
BackgroundMethodSelf-citation
Cited by
Wang, Y., Cheng, X., Jabban, L., Sui, X., & Zhang, D. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3167686 · Cited by 70
Xu, D., Feng, Y., Mai, J., & Wang, Q. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2870152 · Cited by 67
“According to previous study mentioned in [24], the threshold was calculated as”
MethodSelf-citationWhole body awareness for controlling a robotic transfemoral prosthesis
Parri, A., Martini, E., Geeroms, J., Flynn, L., Pasquini, G., Crea, S., Molino Lova, R., Lefeber, D., Kamnik, R., Munih, M., et al. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00025 · Cited by 29
“…interface for powered devices including insole pressure sensing (Wang et al., 2013; Chen et al., 2015; Yuan et al., 2015), capacitive sensing (Zheng et al., 2014), load cells (Varol and Goldfarb, 2007), and IMUs (Maqbool et al., 2016) to identify transitions in lower limb prostheses with…”
Background
Metadata
- Authors
- Zheng, E., Wang, L., Wei, K., & Wang, Q.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-12
- Volume
- 61
- Issue
- 12
- Pages
- 2911-2920
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1978332670
- Cited by
- 87
- References
- 2
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Noncontact Capacitive Sensing System for Recognizing Locomotion Modes of Transtibial Amputees. https://app.cochat.ai/papers/10.1109/tbme.2014.2334316
- The paper
- Zheng, E., Wang, L., Wei, K., & Wang, Q. (2014). A Noncontact Capacitive Sensing System for Recognizing Locomotion Modes of Transtibial Amputees. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2014.2334316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.