Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Motion Intention Prediction and Joint Trajectories Generation Toward Lower Limb Prostheses Using EMG and IMU Signals

Abstract

Powered intelligent lower limb prostheses have been gaining interest as they provide functionality for walking on different terrains. This study proposes a hierarchical planner for intelligent lower limb prostheses based on sensor fusion and a central pattern generator (CPG). Electromyographic (EMG) and inertial measurement unit (IMU) signals were recorded and fused in the feature and decision levels. The high-level planner consists of cascade classifiers with a gait phase dependence. A secondary classifier for each stand phase and swing phase was developed to recognize five gait patterns. The mid-level planner was designed as a walking frequency estimator based on the Newton method. The low-level planner incorporates the CPG models, achieving the planning of lower limb joint trajectories. The proposed layered planner can recognize the users’ walking intention and gait speed in real-time, ensuring coordination between the joints of both legs. Eight healthy subjects were recruited, and the average accuracy of motion pattern recognition reached 99.13% and 99.39% for the standing and swing phases, respectively. The relative root mean square error (RMSE) of the walking frequency estimate was 2.3% under approximately 3.5 m/s gait speed. The promising results indicate that this method effectively predicts the continuous joint angle for lower limb prostheses.

Overview

Integrity signals

Registry

Crossref · 10.1109/jsen.2022.3167686

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 42 references

Cited by

See all 73

Metadata

Authors
Wang, Y., Cheng, X., Jabban, L., Sui, X., & Zhang, D.
Affiliations
  • Shanghai Jiao Tong University (CN)
  • University of Bath (GB)
Venue
IEEE Sensors Journal
Published
2022-06-01
Volume
22
Issue
11
Pages
10719-10729
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W4226101141
Cited by
70
References
42
Citations by year
2026: 17 · 2025: 26 · 2024: 17 · 2023: 9 · 2022: 1
FWCI
3.85
Type
journal article
Language
en
Open access
closed
Locations
IEEE Sensors Journal (publishedVersion)
Funders
  • National Key Research and Development Program of China (2018YFB1307301)
  • National Natural Science Foundation of China (91848112, 62176158)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Locomotion and Control
Keywords
lower limb prosthesis, joint trajectory generation, central pattern generator, gait phase detection, hierarchical motion planning, gait speed estimation, powered prostheses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion Intention Prediction and Joint Trajectories Generation Toward Lower Limb Prostheses Using EMG and IMU Signals. https://app.cochat.ai/papers/10.1109/jsen.2022.3167686
The paper
Wang, Y., Cheng, X., Jabban, L., Sui, X., & Zhang, D. (2022). Motion Intention Prediction and Joint Trajectories Generation Toward Lower Limb Prostheses Using EMG and IMU Signals. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2022.3167686

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.