The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Doppler Radar Fall Activity Detection Using the Wavelet Transform
Abstract
We propose in this paper the use of Wavelet transform (WT) to detect human falls using a ceiling mounted Doppler range control radar. The radar senses any motions from falls as well as nonfalls due to the Doppler effect. The WT is very effective in distinguishing the falls from other activities, making it a promising technique for radar fall detection in nonobtrusive inhome elder care applications. The proposed radar fall detector consists of two stages. The prescreen stage uses the coefficients of wavelet decomposition at a given scale to identify the time locations in which fall activities may have occurred. The classification stage extracts the time-frequency content from the wavelet coefficients at many scales to form a feature vector for fall versus nonfall classification. The selection of different wavelet functions is examined to achieve better performance. Experimental results using the data from the laboratory and real inhome environments validate the promising and robust performance of the proposed detector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
Cited by
Radar Signal Processing for Elderly Fall Detection: The future for in-home monitoring
Amin, M. G., Zhang, Y. D., Ahmad, F., & Ho, K. C. D. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2015.2502784 · Cited by 414
Self-citationVital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
Mercuri, M., Lorato, I. R., Liu, Y.-H., Wieringa, F., Hoof, C. V., & Torfs, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0258-6 · Cited by 354
Seyfioglu, M. S., Ozbayoglu, A. M., & Gurbuz, S. Z. (2018) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2018.2799758 · Cited by 352
FallDeFi: Ubiquitous Fall Detection using Commodity Wi-Fi Devices
Palipana, S., Rojas, D., Agrawal, P., & Pesch, D. (2018) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3161183 · Cited by 279
Illuminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
Metadata
- Authors
- Su, B. Y., Ho, K. C., Rantz, M. J., & Skubic, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-03
- Volume
- 62
- Issue
- 3
- Pages
- 865-875
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2082361295
- Cited by
- 242
- References
- 2
- FWCI
- 13.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.