The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
On the Opportunities and Challenges in Microwave Medical Sensing and Imaging
Abstract
Widely used medical imaging systems in clinics currently rely on X-rays, magnetic resonance imaging, ultrasound, computed tomography, and positron emission tomography. The aforementioned technologies provide clinical data with a variety of resolution, implementation cost, and use complexity, where some of them rely on ionizing radiation. Microwave sensing and imaging (MSI) is an alternative method based on nonionizing electromagnetic (EM) signals operating over the frequency range covering hundreds of megahertz to tens of gigahertz. The advantages of using EM signals are low health risk, low cost implementation, low operational cost, ease of use, and user friendliness. Advancements made in microelectronics, material science, and embedded systems make it possible for miniaturization and integration into portable, handheld, mobile devices with networking capability. MSI has been used for tumor detection, blood clot/stroke detection, heart imaging, bone imaging, cancer detection, and localization of in-body RF sources. The fundamental notion of MSI is that it exploits the tissue-dependent dielectric contrast to reconstruct signals and images using radar-based or tomographic imaging techniques. This paper presents a comprehensive overview of the active MSI for various medical applications, for which the motivation, challenges, possible solutions, and future directions are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
Joines, W. T., Zhang, Y., Li, C., & Jirtle, R. L. (1994) · Medical Physics · doi:10.1118/1.597312 · Cited by 763
Microwave Imaging for Breast Cancer
Nikolova, N. (2011) · IEEE Microwave Magazine · doi:10.1109/mmm.2011.942702 · Cited by 640
Microwave System for Head Imaging
Mohammed, B. J., Abbosh, A. M., Mustafa, S., & Ireland, D. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2277562 · Cited by 384
Microwave-Based Stroke Diagnosis Making Global Prehospital Thrombolytic Treatment Possible
Persson, M., Fhager, A., Trefna, H. D., Yu, Y., McKelvey, T., Pegenius, G., Karlsson, J.-E., & Elam, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2330554 · Cited by 380
Dielectric Properties of Biological Materials: Biophysical and Medical Applications
Pethig, R. (1984) · IEEE Transactions on Electrical Insulation · doi:10.1109/tei.1984.298769 · Cited by 363
Diederich, C. J. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500271692 · Cited by 347
Microwave imaging-complex permittivity reconstruction with a Levenberg-Marquardt method
Franchois, A., & Pichot, C. (1997) · IEEE Transactions on Antennas and Propagation · doi:10.1109/8.560338 · Cited by 312
Schepps, J. L., & Foster, K. R. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/6/012 · Cited by 306
Lazebnik, M., Okoniewski, M., Booske, J. H., & Hagness, S. C. (2007) · IEEE Microwave and Wireless Components Letters · doi:10.1109/lmwc.2007.910465 · Cited by 279
Microwave Tomography for Brain Imaging: Feasibility Assessment for Stroke Detection
Semenov, S. Y., & Corfield, D. R. (2008) · International Journal of Antennas and Propagation · doi:10.1155/2008/254830 · Cited by 251
Microwave tomography: review of the progress towards clinical applications
Semenov, S. Y. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2009.0092 · Cited by 224
Lazebnik, M., Converse, M. C., Booske, J. H., & Hagness, S. C. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/022 · Cited by 194
Shea, J. D., Kosmas, P., Van Veen, B. D., & Hagness, S. C. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/7/074009 · Cited by 158
Clinical Microwave Tomographic Imaging of the Calcaneus: A First-in-Human Case Study of Two Subjects
Meaney, P. M., Goodwin, D. W., Golnabi, A. H., Zhou, T., Pallone, M. J., Geimer, S. D., Burke, G. C., & Paulsen, K. D. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2209202 · Cited by 129
Computational modeling of three-dimensional microwave tomography of breast cancer
Bulyshev, A., Semenov, S. Y., Souvorov, A. E., Svenson, R. H., Nazarov, A. G., Sizov, Y. E., & Tatsis, G. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.942596 · Cited by 127
Electromagnetic interference in critical care
Lapinsky, S. E., & Easty, A. (2006) · Journal of Critical Care · doi:10.1016/j.jcrc.2006.03.010 · Cited by 113
Celik, N., Perron, R. R. G., Huang, G. C., Iskander, M. F., & Berg, B. W. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2241763 · Cited by 104
Microwave tomography: a two-dimensional Newton iterative scheme
Souvorov, A. E., Bulyshev, A., Semenov, S. Y., Svenson, R. H., Nazarov, A. G., Sizov, Y. E., & Tatsis, G. (1998) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.734548 · Cited by 82
Three-dimensional microwave tomography. Theory and computer experiments in scalar approximation
Bulyshev, A., Souvorov, A. E., Semenov, S. Y., Svenson, R. H., Nazarov, A. G., Sizov, Y. E., & Tatsis, G. P. (2000) · Inverse Problems · doi:10.1088/0266-5611/16/3/319 · Cited by 58
Microwave tomography for functional imaging of extremity soft tissues: feasibility assessment
Semenov, S. Y., Kellam, J. F., Althausen, P. L., Williams, T., Abubakar, A., Bulyshev, A., & Sizov, Y. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/015 · Cited by 53
Sunaga, T., Ikehira, H., Furukawa, S., Shinkai, H., Kobayashi, H., Matsumoto, Y., Yoshitome, E., Obata, T., Tanada, S., Murata, H., et al. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/402 · Cited by 49
Santorelli, A., Porter, E., Kirshin, E., Liu, Y. J., & Popović, M. (2014) · Electromagnetic waves · doi:10.2528/pier13110709 · Cited by 41
Cited by
Microwave Breast Imaging: Clinical Advances and Remaining Challenges
O’Loughlin, D., O’Halloran, M., Moloney, B. M., Glavin, M., Jones, E., & Elahi, M. A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2809541 · Cited by 307
Glioblastoma Therapy: Past, Present and Future
Obrador, E., Moreno-Murciano, P., Oriol-Caballo, M., López-Blanch, R., Pineda, B., Gutiérrez-Arroyo, J., Loras, A., Gonzalez-Bonet, L., Martinez-Cadenas, C., Estrela, J., et al. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25052529 · Cited by 271
Metadata
- Authors
- Chandra, R., Zhou, H., Balasingham, I., & Narayanan, R. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-07
- Volume
- 62
- Issue
- 7
- Pages
- 1667-1682
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1929507333
- Cited by
- 418
- References
- 26
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.