Deep Transcranial Magnetic Stimulation: Modeling of Different Coil Configurations
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Deep transcranial magnetic stimulation (dTMS) has been recently used in several clinical studies as diagnostic and therapeutic tool. However, electric field (E) distributions induced in the brain by dTMS are still unknown. This paper provides a characterization of the induced E distributions in the brain of a realistic human model due to 16 different coil configurations. METHODS: The scalar potential finite-element method was used to calculate the E distributions differentiating the brain structures, e.g., cortex, white matter, anterior cingulated cortex, cerebellum, thalamus, hypothalamus, nucleus accumbens, amygdale, and hippocampus. RESULTS: Our results support that the double cone coils and the large diameter circular coils are more prone to activate deeper brain structures but are also characterized by a reduced focality on the surface of the cortex, with the consequent possible counter effect of stimulating regions not of interest. The Hesed coils, although their ability to reach deep brain tissues is lower, seem to be more able to reduce the effect on other brain regions where the stimulation is undesired. CONCLUSION: All the coil configurations resulted subjected to a depth-focality tradeoff. SIGNIFICANCE: Since there is not a configuration that is capable of achieving a stimulation both deep and focal, the selection of the most suitable coil settings for a specific clinical application should be based on a balanced evaluation between these two different needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coil design considerations for deep transcranial magnetic stimulation
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.038 · Cited by 308
Levkovitz, Y., Harel, E. V., Roth, Y., Braw, Y., Most, D., Katz, L. N., Sheer, A., Gersner, R., & Zangen, A. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.08.002 · Cited by 217
Bersani, F. S., Minichino, A., Enticott, P. G., Mazzarini, L., Khan, N., Antonacci, G., Raccah, R. N., Salviati, M., Delle Chiaie, R., Bersani, G., et al. (2013) · European Psychiatry · doi:10.1016/j.eurpsy.2012.02.006 · Cited by 169 · cited 1×
“ing these new coils, several clinical studies showed that dTMS is effective in treating a very wide range of neurological and psychiatric conditions [5], e.”
BackgroundLevkovitz, Y., Rabany, L., Harel, E. V., & Zangen, A. (2011) · International Journal of Neuropsychopharmacology · doi:10.1017/s1461145711000642 · Cited by 87
Cited by
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
Deep transcranial magnetic stimulation (dTMS)—Beyond depression
Tendler, A., Barnea Ygael, N., Roth, Y., & Zangen, A. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1233812 · Cited by 93
Trapp, N. T., Purgianto, A., Taylor, J. J., Singh, M. K., Oberman, L. M., Mickey, B. J., Youssef, N. A., Solzbacher, D., Zebley, B., Cabrera, L. Y., et al. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2024.12.015 · Cited by 89
Van Hoornweder, S., Nuyts, M., Frieske, J., Verstraelen, S., Meesen, R. L. J., & Caulfield, K. A. (2023) · doi:10.1101/2023.02.22.529540 · Cited by 37
Shanok, N. A., Rodriguez, S., Muzac, S., Huertas Del Pino, C., Brown, L., & Rodriguez, R. (2023) · Journal of Affective Disorders · doi:10.1016/j.jad.2023.05.066 · Cited by 14
Metadata
- Authors
- Guadagnin, V., Parazzini, M., Fiocchi, S., Liorni, I., & Ravazzani, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-07
- Volume
- 63
- Issue
- 7
- Pages
- 1543-1550
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2343031690
- Cited by
- 101
- References
- 4
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.