The DOI matches its Crossref record.
High-Performance Personalized Heartbeat Classification Model for Long-Term ECG Signal
Abstract
Long-term electrocardiogram (ECG) has become one of the important diagnostic assist methods in clinical cardiovascular domain. Long-term ECG is primarily used for the detection of various cardiovascular diseases that are caused by various cardiac arrhythmia such as myocardial infarction, cardiomyopathy, and myocarditis. In the past few years, the development of an automatic heartbeat classification method has been a challenge. With the accumulation of medical data, personalized heartbeat classification of a patient has become possible. For the long-term data accumulation method, such as the holter, it is difficult to obtain the analysis results in a short time using the original method of serial design. The pressure to develop a personalized automatic classification model is high. To solve these challenges, this paper implemented a parallel general regression neural network (GRNN) to classify the heartbeat, and achieved a 95% accuracy according to the Association for the Advancement of Medical Instrumentation. We designed an online learning program to form a personalized classification model for patients. The achieved accuracy of the model is 88% compared to the specific ECG data of the patients. The efficiency of the parallel GRNN with GTX780Ti can improve by 450 times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
LSTM-Based ECG Classification for Continuous Monitoring on Personal Wearable Devices
Saadatnejad, S., Oveisi, M., & Hashemi, M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2911367 · Cited by 406
LSTM-Based Auto-Encoder Model for ECG Arrhythmias Classification
Hou, B., Yang, J., Wang, P., & Yan, R. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2910342 · Cited by 307
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Metadata
- Authors
- Li, P., Wang, Y., He, J., Wang, L., Tian, Y., Zhou, T.-S., Li, T., & Li, J.-S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-01
- Volume
- 64
- Issue
- 1
- Pages
- 78-86
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2333414777
- Cited by
- 159
- References
- 0
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Performance Personalized Heartbeat Classification Model for Long-Term ECG Signal. https://app.cochat.ai/papers/10.1109/tbme.2016.2539421
- The paper
- Li, P., Wang, Y., He, J., Wang, L., Tian, Y., Zhou, T.-S., Li, T., & Li, J.-S. (2017). High-Performance Personalized Heartbeat Classification Model for Long-Term ECG Signal. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2016.2539421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.