The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
LSTM-Based Auto-Encoder Model for ECG Arrhythmias Classification
Abstract
This paper introduces a novel deep learning-based algorithm that integrates a long short-term memory (LSTM)-based auto-encoder (AE) network with support vector machine (SVM) for electrocardiogram (ECG) arrhythmias classification. The LSTM-based AE network (LSTM-AE) is used to learn the features from ECG arrhythmias signals, and the SVM is used to classify those signals from the learned features. The LSTM-AE consists of an encoder model, which extracts high-level feature information from ECG arrhythmias signals through LSTM network, and a decoder model which outputs reconstruct ECG arrhythmias signals from high-level features through LSTM network. Experiments show that the proposed method can learn better features than the traditional method without any prior knowledge, presenting a good potential for the ECG arrhythmias classification. In the classification of five heartbeats types, including normal, left bundle branch block (LBBB), right bundle branch block (RBBB), atrial premature complexes (APC), premature ventricular contractions (PVC), the proposed method achieved average accuracy, sensitivity, and specificity of 99.74%, 99.35%, and 99.84%, respectively, in the beat-based cross-validation approach, and 85.20%, 62.99%, and 90.75%, respectively, in the record-based cross-validation approach, in public MIT-BIH Arrhythmia Database. While based on the Advancement of Medical Instrumentation (AAMI) standards, the proposed method achieved average accuracy, sensitivity, and specificity of 99.45%, 98.63%, and 99.66%, respectively, in the beat-based cross-validation approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
Kiranyaz, S., Ince, T., & Gabbouj, M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468589 · Cited by 1,912
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
A deep convolutional neural network model to classify heartbeats
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., Adam, M., Gertych, A., & Tan, R. S. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.022 · Cited by 1,421
Yildirim, Ö. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.03.016 · Cited by 833
Oh, S. L., Ng, E. Y. K., Tan, R. S., & Acharya, U. R. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.06.002 · Cited by 729
Deep learning approach for active classification of electrocardiogram signals
Rahhal, M. M. A., Bazi, Y., AlHichri, H., Alajlan, N., Melgani, F., & Yager, R. R. (2016) · Information Sciences · doi:10.1016/j.ins.2016.01.082 · Cited by 627
Support Vector Machine-Based Expert System for Reliable Heartbeat Recognition
Osowski, S., Hoai, L. T., & Markiewicz, T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824138 · Cited by 536
Heartbeat Classification Using Morphological and Dynamic Features of ECG Signals
Ye, C., Kumar, B. V. K. V., & Coimbra, M. T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2213253 · Cited by 522
Optimal selection of wavelet basis function applied to ECG signal denoising
Singh, B. N., & Tiwari, A. K. (2006) · Digital Signal Processing · doi:10.1016/j.dsp.2005.12.003 · Cited by 509
ECG Classification Using Wavelet Packet Entropy and Random Forests
Li, T., & Zhou, M. (2016) · Entropy · doi:10.3390/e18080285 · Cited by 478
Cited by
Deep learning in ECG diagnosis: A review
Liu, X., Wang, H., Li, Z., & Qin, L. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107187 · Cited by 436
Murat, F., Yildirim, O., Talo, M., Baloglu, U. B., Demir, Y., & Acharya, U. R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103726 · Cited by 326
A Review of Recurrent Neural Network-Based Methods in Computational Physiology
Mao, S., & Sejdić, E. (2023) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2022.3145365 · Cited by 128
A Holistic Feature Selection Method for Enhanced Short-term Load Forecasting of Power System
Jiang, B., Liu, Y., Geng, H., Wang, Y., Zeng, H., & Ding, J. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3219499 · Cited by 46
Generating Healthcare Time Series Data for Improving Diagnostic Accuracy of Deep Neural Networks
Maweu, B. M., Shamsuddin, R., Dakshit, S., & Prabhakaran, B. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3077049 · Cited by 35
Metadata
- Authors
- Hou, B., Yang, J., Wang, P., & Yan, R.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2020-04
- Volume
- 69
- Issue
- 4
- Pages
- 1232-1240
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2942497026
- Cited by
- 307
- References
- 35
- FWCI
- 22.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: LSTM-Based Auto-Encoder Model for ECG Arrhythmias Classification. https://app.cochat.ai/papers/10.1109/tim.2019.2910342
- The paper
- Hou, B., Yang, J., Wang, P., & Yan, R. (2020). LSTM-Based Auto-Encoder Model for ECG Arrhythmias Classification. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2019.2910342
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.