The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Evaluation of Six Registration Methods for the Human Abdomen on Clinically Acquired CT
Open accessAbstract
OBJECTIVE: This work evaluates current 3-D image registration tools on clinically acquired abdominal computed tomography (CT) scans. METHODS: Thirteen abdominal organs were manually labeled on a set of 100 CT images, and the 100 labeled images (i.e., atlases) were pairwise registered based on intensity information with six registration tools (FSL, ANTS-CC, ANTS-QUICK-MI, IRTK, NIFTYREG, and DEEDS). The Dice similarity coefficient (DSC), mean surface distance, and Hausdorff distance were calculated on the registered organs individually. Permutation tests and indifference-zone ranking were performed to examine the statistical and practical significance, respectively. RESULTS: The results suggest that DEEDS yielded the best registration performance. However, due to the overall low DSC values, and substantial portion of low-performing outliers, great care must be taken when image registration is used for local interpretation of abdominal CT. CONCLUSION: There is substantial room for improvement in image registration for abdominal CT. SIGNIFICANCE: All data and source code are available so that innovations in registration can be directly compared with the current generation of tools without excessive duplication of effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationEvaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citationWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Multi-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
Cited by
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
Gibson, E., Giganti, F., Hu, Y., Bonmati, E., Bandula, S., Gurusamy, K., Davidson, B., Pereira, S. P., Clarkson, M. J., & Barratt, D. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2806309 · Cited by 697
Evaluation of algorithms for Multi-Modality Whole Heart Segmentation: An open-access grand challenge
Zhuang, X., Li, L., Payer, C., Štern, D., Urschler, M., Heinrich, M. P., Oster, J., Wang, C., Smedby, Ö., Bian, C., et al. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101537 · Cited by 361
Self-citation
Metadata
- Authors
- Xu, Z., Lee, C. P., Heinrich, M. P., Modat, M., Rueckert, D., Ourselin, S., Abramson, R. G., & Landman, B. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-08
- Volume
- 63
- Issue
- 8
- Pages
- 1563-1572
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2413073178
- Cited by
- 175
- References
- 4
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Six Registration Methods for the Human Abdomen on Clinically Acquired CT. https://app.cochat.ai/papers/10.1109/tbme.2016.2574816
- The paper
- Xu, Z., Lee, C. P., Heinrich, M. P., Modat, M., Rueckert, D., Ourselin, S., Abramson, R. G., & Landman, B. A. (2016). Evaluation of Six Registration Methods for the Human Abdomen on Clinically Acquired CT. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2016.2574816
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.