CoChat

Semi-supervised Stacked Label Consistent Autoencoder for Reconstruction and Analysis of Biomedical Signals

Gogna, Anupriya, Majumdar, Angshul, Ward, Rabab · 2017 · IEEE Transactions on Biomedical Engineering
Cited by 147

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: An autoencoder-based framework that simultaneously reconstruct and classify biomedical signals is proposed. Previous work has treated reconstruction and classification as separate problems. This is the first study that proposes a combined framework to address the issue in a holistic fashion. METHODS: For telemonitoring purposes, reconstruction techniques of biomedical signals are largely based on compressed sensing (CS); these are "designed" techniques where the reconstruction formulation is based on some "assumption" regarding the signal. In this study, we propose a new paradigm for reconstruction-the reconstruction is "learned," using an autoencoder; it does not require any assumption regarding the signal as long as there is sufficiently large training data. But since the final goal is to analyze/classify the signal, the system can also learn a linear classification map that is added inside the autoencoder. The ensuing optimization problem is solved using the Split Bregman technique. RESULTS: Experiments were carried out on reconstructing and classifying electrocardiogram (ECG) (arrhythmia classification) and EEG (seizure classification) signals. CONCLUSION: Our proposed tool is capable of operating in a semi-supervised fashion. We show that our proposed method is better in reconstruction and more than an order magnitude faster than CS based methods; it is capable of real-time operation. Our method also yields better results than recently proposed classification methods. SIGNIFICANCE: This is the first study offering an alternative to CS-based reconstruction. It also shows that the representation learning approach can yield better results than traditional methods that use hand-crafted features for signal analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2016.2631620

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 147

Metadata

Authors
Gogna, A., Majumdar, A., & Ward, R.
Venue
IEEE Transactions on Biomedical Engineering
Published
2017-09
Volume
64
Issue
9
Pages
2196-2205
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2556806401
Cited by
147
References
8
FWCI
11.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Semi-supervised Stacked Label Consistent Autoencoder for Reconstruction and Analysis of Biomedical Signals. https://app.cochat.ai/papers/10.1109/tbme.2016.2631620
The paper
Gogna, A., Majumdar, A., & Ward, R. (2017). Semi-supervised Stacked Label Consistent Autoencoder for Reconstruction and Analysis of Biomedical Signals. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2016.2631620

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.