The DOI matches its Crossref record; 47 of the 51 references it cites were found in a registry or an index.
On the Carbon Footprint Optimization in an InterCloud Environment
Abstract
In this paper, we address the problem of Virtual Machine (VM) placement in an InterCloud with regard to the reduction of carbon footprint in such computing environment. In order to minimize data centers’ Greenhouse Gas (GhG) emissions, this paper proposes a mathematical formulation, where the placement approach is stated as a Mixed-Integer Nonlinear Programming (MINLP) problem which aims at minimizing the carbon footprint of the InterCloud. The proposed formulation presents an accurate carbon footprint evaluation based on joint optimization techniques, such as smart and performance-aware workload consolidation, along with cooling efficiency maximization, while considering the greenness factor of the data centers and the dynamic behavior of the equipment cooling fans. Simulations with an exact method showed that, compared with other baseline approaches, the proposed mathematical model leads to optimal configurations with minimal GhG emissions in a single cloud, as well as in an InterCloud environment, and can yield savings of up to 65 percent. The proposed model has also been compared with an approach that performs blind VM consolidation, and the obtained results showed that such model can simultaneously lead to VM configuration that yields the minimum carbon footprint while performing smart VM consolidation in order to prevent Service Level Agreement (SLA) violations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Buyya, R., Yeo, C. S., Venugopal, S., Broberg, J., & Brandic, I. (2009) · Future Generation Computer Systems · doi:10.1016/j.future.2008.12.001 · Cited by 5,937 · cited 1×
“[31] introduced a model for VM power metering, based on which, approaches for placing Virtual Machines (VMs) with regard to the energy minimization were developed [5], [32], [33] and [34].”
The Case for Energy-Proportional Computing
Barroso, L. A., & Hölzle, U. (2007) · Computer · doi:10.1109/mc.2007.443 · Cited by 2,491 · cited 1×
“Techniques, such as Dynamic Voltage and Frequency Scaling [19], [20] and CPU idle power saving states [21], were developed to increase servers’ energy efficiency [22], [23], [24].”
MethodA dynamic voltage scaled microprocessor system
Burd, T. D., Pering, T. A., Stratakos, A. J., & Brodersen, R. W. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.881202 · Cited by 916 · cited 1×
“Techniques, such as Dynamic Voltage and Frequency Scaling [19], [20] and CPU idle power saving states [21], were developed to increase servers’ energy efficiency [22], [23], [24].”
MethodVirtual Network Embedding with Coordinated Node and Link Mapping
Chowdhury, N. M. M. K., Rahman, M. R., & Boutaba, R. (2009) · IEEE INFOCOM 2009 · doi:10.1109/infcom.2009.5061987 · Cited by 823 · cited 1×
“NOWADAYS, Cloud Computing provides innovative computing solutions [1], [2], allowing small businesses to rent virtual servers as a service.”
BackgroundEnergy aware consolidation for cloud computing
Srikantaiah, S., Kansal, A., & Zhao, F. (2008) · Cited by 784
Algorithms for Assigning Substrate Network Resources to Virtual Network Components
Zhu, Y., & Ammar, M. (2006) · Proceedings IEEE INFOCOM 2006. 25TH IEEE International Conference on Computer Communications · doi:10.1109/infocom.2006.322 · Cited by 779 · cited 1×
“NOWADAYS, Cloud Computing provides innovative computing solutions [1], [2], allowing small businesses to rent virtual servers as a service.”
BackgroundPower and performance management of virtualized computing environments via lookahead control
Kusic, D., Kephart, J. O., Hanson, J. E., Kandasamy, N., & Jiang, G. (2009) · Cluster Computing · doi:10.1007/s10586-008-0070-y · Cited by 699 · cited 1×
“[47] tried to minimize both power consumption and SLA violations in order to maximize the provider’s profit.”
BackgroundMaking scheduling cool: temperature-aware workload placement in data centers
Moore, J., Chase, J., Ranganathan, P., & Sharma, R. K. (2005) · USENIX Annual Technical Conference · Cited by 651
Energy efficient utilization of resources in cloud computing systems
Lee, Y. C., & Zomaya, A. Y. (2012) · The Journal of Supercomputing · doi:10.1007/s11227-010-0421-3 · Cited by 647 · cited 2×
“The linear model suggested by [15] and [52] is used to eval-”
Virtual machine power metering and provisioning
Kansal, A., Zhao, F., Liu, J., Kothari, N., & Bhattacharya, A. A. (2010) · Proceedings of the 1st ACM symposium on Cloud computing · doi:10.1145/1807128.1807136 · Cited by 556 · cited 1×
“[31] introduced a model for VM power metering, based on which, approaches for placing Virtual Machines (VMs) with regard to the energy minimization were developed [5], [32], [33] and [34].”
MethodEntropy: a consolidation manager for clusters
Hermenier, F., Lorca, X., Menaud, J.-M., Muller, G., & Lawall, J. (2009) · Proceedings of the 2009 ACM SIGPLAN/SIGOPS international conference on Virtual execution environments · doi:10.1145/1508293.1508300 · Cited by 479 · cited 1×
“However, its adoption comes with challenges, such as the VM placement problem [3], [4], which tends to find the most convenient hosts for the VMs, based on optimization criteria.”
BackgroundBalance of Power: Dynamic Thermal Management for Internet Data Centers
Sharma, R. K., Bash, C. E., Patel, C. D., Friedrich, R. J., & Chase, J. S. (2005) · IEEE Internet Computing · doi:10.1109/mic.2005.10 · Cited by 443 · cited 1×
“As the cooling cost accounts for about 30 percent of a data center’s power cost [35], heat extracting methods [36], [37] were proposed in order to reduce the cooling energy.”
MethodBuyya, R., Beloglazov, A., & Abawajy, J. (2010) · doi:10.48550/arxiv.1006.0308 · Cited by 440 · cited 1×
“Other works, such as [3], [26], [27], [28] and [29], provided consolidation tools to reduce the amount of in-use hardware.”
BackgroundRenewable and cooling aware workload management for sustainable data centers
Liu, Z., Chen, Y., Bash, C., Wierman, A., Gmach, D., Wang, Z., Marwah, M., & Hyser, C. (2012) · Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems · doi:10.1145/2254756.2254779 · Cited by 413 · cited 1×
“[41] proposed a workload placement approach based on the available renewable energy sources and the cooling efficiency in order to minimize the operational cost of a data center.”
BackgroundBuyya, R., Beloglazov, A., & Abawajy, J. (2010) · Minerva Access (University of Melbourne) · Cited by 380
Model Building in Mathematical Programming.
Bunday, B. D., & Williams, H. P. (1985) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2981914 · Cited by 356
Energy-Aware Ant Colony Based Workload Placement in Clouds
Feller, E., Rilling, L., & Morin, C. (2011) · 2011 IEEE/ACM 12th International Conference on Grid Computing · doi:10.1109/grid.2011.13 · Cited by 322 · cited 1×
“Other works, such as [3], [26], [27], [28] and [29], provided consolidation tools to reduce the amount of in-use hardware.”
BackgroundEnaCloud: An Energy-Saving Application Live Placement Approach for Cloud Computing Environments
Li, B., Li, J., Huai, J., Wo, T., Li, Q., & Zhong, L. (2009) · 2009 IEEE International Conference on Cloud Computing · doi:10.1109/cloud.2009.72 · Cited by 313 · cited 1×
“Other works, such as [3], [26], [27], [28] and [29], provided consolidation tools to reduce the amount of in-use hardware.”
BackgroundPower-aware scheduling of virtual machines in DVFS-enabled clusters
von Laszewski, G., Wang, L., Younge, A. J., & He, X. (2009) · 2009 IEEE International Conference on Cluster Computing and Workshops · doi:10.1109/clustr.2009.5289182 · Cited by 285 · cited 1×
“Moreover, multiple management methods for computing nodes [11], and workload consolidation techniques have been largely implemented by cloud providers in order to address the issue of high power consumption of data centers and their associated carbon footprint.”
Shares and utilities based power consolidation in virtualized server environments
Cardosa, M., Korupolu, M. R., & Singh, A. (2009) · 2009 IFIP/IEEE International Symposium on Integrated Network Management · doi:10.1109/inm.2009.5188832 · Cited by 262 · cited 2×
“Other works, such as [3], [26], [27], [28] and [29], provided consolidation tools to reduce the amount of in-use hardware.”
BackgroundCritical power slope: understanding the runtime effects of frequency scaling
Miyoshi, A., Lefurgy, C., Van Hensbergen, E., Rajamony, R., & Rajkumar, R. (2002) · Proceedings of the 16th international conference on Supercomputing · doi:10.1145/514191.514200 · Cited by 231 · cited 1×
“Techniques, such as Dynamic Voltage and Frequency Scaling [19], [20] and CPU idle power saving states [21], were developed to increase servers’ energy efficiency [22], [23], [24].”
MethodGeographical load balancing with renewables
Liu, Z., Lin, M., Wierman, A., Low, S. H., & Andrew, L. L. H. (2011) · ACM SIGMETRICS Performance Evaluation Review · doi:10.1145/2160803.2160862 · Cited by 221 · cited 1×
“of wind/solar energies in order to reduce the brown energy consumption in [44].”
BackgroundMinimizing data center cooling and server power costs
Pakbaznia, E., & Pedram, M. (2009) · Proceedings of the 2009 ACM/IEEE international symposium on Low power electronics and design · doi:10.1145/1594233.1594268 · Cited by 218 · cited 7×
“The third method, CB MAX TEMP, performs carbon footprint minimization while maximizing the CRAC unit efficiency by considering the maximal value of the temperature (35 C) [12].”
BackgroundMethodInfluentialSensor-Based Fast Thermal Evaluation Model For Energy Efficient High-Performance Datacenters
Tang, Q., Mukherjee, T., Gupta, S. K. S., & Cayton, P. (2006) · 2006 Fourth International Conference on Intelligent Sensing and Information Processing · doi:10.1109/icisip.2006.4286097 · Cited by 206 · cited 1×
“[38] proposed a heat flow model which has been used for optimizing the energy cost under server inlet temperature constraints [39], or for minimizing both server and cooling power of a data center [12].”
MethodGreening Geographical Load Balancing
Liu, Z., Lin, M., Wierman, A., Low, S., & Andrew, L. L. H. (2015) · IEEE/ACM Transactions on Networking · doi:10.1109/tnet.2014.2308295 · Cited by 159
Energy and Carbon-Efficient Placement of Virtual Machines in Distributed Cloud Data Centers
Khosravi, A., Garg, S. K., & Buyya, R. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40047-6_33 · Cited by 156 · cited 1×
“[46] addressed the problem of increase in carbon footprint of a computing environment while considering the greenness factors of the cloud sites, their efficiency or Power Usage Effectiveness (PUE) and the servers’ power profiles.”
BackgroundMaximizing Cloud Providers' Revenues via Energy Aware Allocation Policies
Mazzucco, M., Dyachuk, D., & Deters, R. (2010) · IEEE ... International Conference on Cloud Computing · doi:10.1109/cloud.2010.68 · Cited by 146 · cited 2×
“where COPd t ð Þ is given by the following [6]:”
BackgroundCurrent State of Development of Electricity-Generating Technologies: A Literature Review
Lenzen, M. (2010) · Energies · doi:10.3390/en3030462 · Cited by 143 · cited 1×
“The power consumption of a distributed cloud environment does not always reflect its carbon footprint [9]: green data centers will always have zero emission, regardless of their energy consumption, whereas in the case of data centers powered by semi-clean or brown energy sources, their carbon footprint becomes highly…”
BackgroundEnergy-Saving Virtual Machine Placement in Cloud Data Centers
Dong, J., Jin, X., Wang, H., Li, Y., Zhang, P., & Cheng, S. (2013) · IEEE/ACM International Symposium on Cluster, Cloud and Grid Computing (CCGrid) · doi:10.1109/ccgrid.2013.107 · Cited by 138
An energy aware framework for virtual machine placement in cloud federated data centres
Dupont, C., Schulze, T., Giuliani, G., Somov, A., & Hermenier, F. (2012) · ACM International Conference on Future Energy Systems (e-Energy) · doi:10.1145/2208828.2208832 · Cited by 118 · cited 2×
“Until recently, the VM placement problem has been focusing on improving metrics, like performance and service availability [5].”
BackgroundMethodPatel, C. D., Bash, C. E., Sharma, R. K., Beitelmal, M. H., & Friedrich, R. (2003) · ASME International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems (InterPACK) · doi:10.1115/ipack2003-35059 · Cited by 116 · cited 1×
“As the cooling cost accounts for about 30 percent of a data center’s power cost [35], heat extracting methods [36], [37] were proposed in order to reduce the cooling energy.”
MethodLarumbe, F., & Sansò, B. (2013) · IEEE Transactions on Cloud Computing · doi:10.1109/tcc.2013.2 · Cited by 111 · cited 2×
“5) corresponding to the lowest temperature suggested by [13] (15 C) [33].”
BackgroundMethodChallenges Towards Elastic Power Management in Internet Data Centers
Liu, J., Zhao, F., Liu, X., & He, W. (2009) · IEEE International Conference on Distributed Computing Systems Workshops (ICDCSW) · doi:10.1109/icdcsw.2009.44 · Cited by 109 · cited 1×
“Techniques, such as Dynamic Voltage and Frequency Scaling [19], [20] and CPU idle power saving states [21], were developed to increase servers’ energy efficiency [22], [23], [24].”
MethodMatching renewable energy supply and demand in green datacenters
Goiri, Í., Haque, M. E., Le, K., Beauchea, R., Nguyen, T. D., Guitart, J., Torres, J., & Bianchini, R. (2014) · Ad Hoc Networks · doi:10.1016/j.adhoc.2014.11.012 · Cited by 97 · cited 1×
“[42]”
Stratus: Load Balancing the Cloud for Carbon Emissions Control
Doyle, J. C., Shorten, R. N., & O’Mahony, D. (2013) · IEEE Transactions on Cloud Computing · doi:10.1109/tcc.2013.4 · Cited by 94 · cited 1×
“[45] developed a method based on Voronoi partitions that schedules the workload in order to simultaneously reduce the delay, the energy and the carbon footprint cost.”
MethodThermal-Aware Scheduling of Batch Jobs in Geographically Distributed Data Centers
Polverini, M., Cianfrani, A., Ren, S., & Vasilakos, A. V. (2014) · IEEE Transactions on Cloud Computing · doi:10.1109/tcc.2013.2295823 · Cited by 87
Sharifi, M., Salimi, H., & Najafzadeh, M. (2011) · The Journal of Supercomputing · doi:10.1007/s11227-011-0658-5 · Cited by 72
Data center energy efficient resource scheduling
Shuja, J., Bilal, K., Madani, S. A., & Khan, S. U. (2014) · Cluster Computing · doi:10.1007/s10586-014-0365-0 · Cited by 71 · cited 1×
“[31] introduced a model for VM power metering, based on which, approaches for placing Virtual Machines (VMs) with regard to the energy minimization were developed [5], [32], [33] and [34].”
MethodLow Carbon Virtual Private Clouds
Moghaddam, F. F., Cheriet, M., & Nguyen, K. K. (2011) · IEEE ... International Conference on Cloud Computing · doi:10.1109/cloud.2011.36 · Cited by 48 · cited 8×
“As the carbon footprint of a non-green data center is highly related to its power consumption [10], carbon footprint minimization for a data center does involve power consumption reduction, which is not as straightforward as it seems.”
BackgroundMethodInfluentialLi, K. (2015) · IEEE Transactions on Cloud Computing · doi:10.1109/tcc.2015.2440238 · Cited by 48 · cited 1×
“For instance, in [25], Li proposed to dynamically adjust the server core power and speed in order to reduce energy consumption.”
BackgroundVirtual machine consolidation based on interference modeling
Kim, S.-G., Eom, H., & Yeom, H. Y. (2013) · The Journal of Supercomputing · doi:10.1007/s11227-013-0939-2 · Cited by 47 · cited 1×
“In [49], the VM placement algorithm used an interference model that determines the mutual impact of co-located applications.”
MethodDistributed computing for carbon footprint reduction by exploiting low-footprint energy availability
Heddeghem, W. V., Vereecken, W., Colle, D., Pickavet, M., & Demeester, P. (2011) · Future Generation Computer Systems · doi:10.1016/j.future.2011.05.004 · Cited by 45 · cited 1×
“Although a carbon footprint model, based on the binomial distribution was introduced in [43], it cannot accurately evaluate the ecological impact of an InterCloud.”
MethodCarbon Metering and Effective Tax Cost Modeling for Virtual Machines
Moghaddam, F. F., Moghaddam, R. F., & Cheriet, M. (2012) · IEEE ... International Conference on Cloud Computing · doi:10.1109/cloud.2012.110 · Cited by 13 · cited 6×
“The greenness factor is obtained as follows [9]:”
BackgroundMethodInfluentialGreen Computing Strategies for Improving Energy Efficiency in IT Systems
John, J. (2014) · Cited by 10
Approaches Towards Energy-Efficiency in the Cloud for Emerging Markets
Dharwar, D., Bhat, S. S., Srinivasan, V., Sarma, D., & Banerjee, P. K. (2012) · IEEE International Conference on Cloud Computing in Emerging Markets (CCEM) · doi:10.1109/ccem.2012.6354599 · Cited by 6 · cited 1×
“Techniques, such as Dynamic Voltage and Frequency Scaling [19], [20] and CPU idle power saving states [21], were developed to increase servers’ energy efficiency [22], [23], [24].”
MethodAn analysis of the impact of datacenter temperature on energy efficiency
Lee, H. (2012) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 5
A model for carbon footprint optimization in an InterCloud environment
Justafort, V. D., Beaubrun, R., & Pierre, S. (2014) · IEEE International Conference on Cloud Networking · doi:10.1109/cloudnet.2014.6969032 · Cited by 3
Self-citation
Research works printed but not linked: 3
- rasmussen, 2007, Calculating total cooling requirements for data centers, White Paper, 25, 1
- pelley, 2009, Understanding and abstracting total data center power, Proc Workshop Energy-Efficient Design
- 0, Make it green: Cloud computing and its contribution to climate change, Greenpeace International
Cited by
A Bio-Inspired Virtual Machine Placement Toward Sustainable Cloud Resource Management
Singh, A. K., Swain, S. R., Saxena, D., & Lee, C. (2023) · IEEE Systems Journal · doi:10.1109/jsyst.2023.3248118 · Cited by 62
“The CoP metric can be modeled in (8) [34]”
A power and thermal-aware virtual machine management framework based on machine learning
Xiao, P., Ni, Z., Liu, D., & Hu, Z. (2021) · Cluster Computing · doi:10.1007/s10586-020-03228-6 · Cited by 23
Alex, M., Ojo, S. O., & Awuor, F. M. (2025) · Computers · doi:10.3390/computers14070280 · Cited by 22
An Intelligent Straggler Traffic Management Framework for Sustainable Cloud Environments
Swain, S. R., Saxena, D., Kumar, J., Singh, A. K., & Lee, C. (2024) · IEEE Transactions on Sustainable Computing · doi:10.1109/tsusc.2024.3393357 · Cited by 9
“A higher CoP value signifies greater efficiency, indicating that less work is needed to remove a larger amount of heat [25].”
A hybrid approach for optimizing carbon footprint in intercloud environment
Justafort, V. D., Beaubrun, R., & Pierre, S. (2019) · IEEE Transactions on Services Computing · doi:10.1109/tsc.2016.2638900 · Cited by 7
“etition, part of the notation and some constraints introduced in our previous works [12], [13], [14] are only presented in the Appendix, available in the online sup-”
BackgroundMethodSelf-citation
Metadata
- Authors
- Justafort, V. D., Beaubrun, R., & Pierre, S.
- Affiliations
- Polytechnique Montréal (CA)
- Université Laval (CA)
- Venue
- IEEE Transactions on Cloud Computing
- Published
- 2018-07-01
- Volume
- 6
- Issue
- 3
- Pages
- 829-842
- ISSN
- 2168-7161 (ISSN-L)
- 2372-0018
- OpenAlex
- W2343662802
- Cited by
- 10
- References
- 51
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 1
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Cloud Computing (publishedVersion)
- PolyPublie (École Polytechnique de Montréal) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
- Physical Sciences › Computer Science › Hardware and Architecture › Energy Efficiency in Computing
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Green IT and Sustainability
- Keywords
- carbon footprint, inter-cloud, virtual machine placement, greenhouse gas emissions, workload consolidation, green data centers, mixed-integer nonlinear programming, service level agreement violation, energy efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.