Cited by 167Advanced DC-DC ConvertersAdvanced Control Systems DesignAnalog and Mixed-Signal Circuit Design

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Modeling the closed-current loop of PWM boost DC-DC converters operating in CCM with peak current-mode control

Bryant, B., Kazimierczuk, M.K.·2005·IEEE Transactions on Circuits and Systems I: Regular Papers

Abstract

This paper derives the transfer function from error voltage to duty cycle, which captures the quasi-digital behavior of the closed-current loop for pulsewidth modulated (PWM) dc-dc converters operating in continuous-conduction mode (CCM) using peak current-mode (PCM) control, the current-loop gain, the transfer function from control voltage to duty cycle (closed-current loop transfer function), and presents experimental verification. The sample-and-hold effect, or quasi-digital (discrete) behavior in the current loop with constant-frequency PCM in PWM dc-dc converters is described in a manner consistent with the physical behavior of the circuit. Using control theory, a transfer function from the error voltage to the duty cycle that captures the quasi-digital behavior is derived. This transfer function has a pole that can be in either the left-half plane or right-half plane, and captures the sample-and-hold effect accurately, enabling the characterization of the current-loop gain and closed-current loop for PWM dc-dc converters with PCM. The theoretical and experimental response results were in excellent agreement, confirming the validity of the transfer functions derived. The closed-current loop characterization can be used for the design of a controller for the outer voltage loop.

Overview

Integrity signals

Registry

Crossref · 10.1109/tcsi.2005.853904

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 23 references

Cited by

Sorted by citations

Metadata

Authors
Bryant, B., & Kazimierczuk, M. K.
Affiliations
Wright State University (US)
Venue
IEEE Transactions on Circuits and Systems I: Regular Papers
Published
2005-11
Volume
52
Issue
11
Pages
2404-2412
ISSN
1057-7122 (ISSN-L)
OpenAlex
W2169678234
Cited by
167
References
23
Citations by year
2026: 3 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 4 · 2021: 8 · 2020: 7 · 2019: 4 · 2018: 6 · 2017: 7 · 2016: 13 · 2015: 11 · 2014: 16 · 2013: 14 · 2012: 13
FWCI
5.38
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
PWM boost converter, DC-DC converter, peak current mode control, continuous conduction mode, transfer function, duty cycle control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review