Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
Abstract
We present a new circuit topology for potentiostats that interface with three-electrode amperometric electrochemical sensors. In this new topology, a current-copying circuit, e.g., a current mirror, is placed in the sensor current path to generate a mirrored image of the sensor current. The mirrored image is then measured and processed instead of the sensor current itself. The new potentiostat topology consumes very low power, occupies a very small die area, and has potentially very low noise. These characteristics make the new topology very suitable for portable or bioimplantable applications. In order to demonstrate the feasibility of the new topology, we present the results of a potentiostat circuit implemented in a 0.18-mum CMOS process. The circuit converts the sensor current to a frequency-modulated pulse waveform, for which the time difference between two consecutive pulses is inversely proportional to the sensor current. The potentiostat measures the sensor current from 1 nA to 1 muA with better than 0.1% of accuracy. It consumes only 70 muW of power from a 1.8-V supply voltage and occupies an area of 0.02 mm2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Self-citation
Metadata
- Authors
- Ahmadi, M. M., & Jullien, G. A.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2009-07
- Volume
- 56
- Issue
- 7
- Pages
- 1339-1348
- ISSN
- 1549-8328 (ISSN-L)
- 1558-0806
- OpenAlex
- W2146524624
- Cited by
- 179
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors. https://app.cochat.ai/papers/10.1109/tcsi.2008.2005927
- The paper
- Ahmadi, M. M., & Jullien, G. A. (2009). Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors. IEEE Transactions on Circuits and Systems I: Regular Papers. https://doi.org/10.1109/tcsi.2008.2005927
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.