The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Open accessAbstract
A remotely powered implantable microsystem for continuous blood glucose monitoring is presented. The microsystem consists of a microfabricated glucose biosensor flip-chip bonded to a transponder chip. The transponder chip is inductively powered by an external reader with a 13.56-MHz carrier. It then measures the output signal of the glucose biosensor and transmits the measured data back to the external reader using load-shift keying (LSK). The microsystem has a volume of 32 mm(3). The procedures for the microfabrication of the glucose sensor and the assembly of the microsystem are described along with the description of the circuit blocks of the transponder chip. The transponder chip has been fabricated with the TSMC 0.18-mum CMOS process and has a total area of 1.3 x 1.3 mm(2). The chip can measure the sensor output current ranging from 1 nA to 1 muA with less than 0.3% nonlinearity error, provided that the amplitude of the received RF signal is higher than 2.6 V; the circuit consumes a total current of about 110 muA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,435
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
Biosensors: fundamentals and applications
Turner, A. P. F., Karube, I., Wilson, G. S., & Worsfold, P. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85361-1 · Cited by 1,320
A CMOS bandgap reference circuit with sub-1-V operation
Banba, H., Shiga, H., Umezawa, A., Miyaba, T., Tanzawa, T., Atsumi, S., & Sakui, K. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.760378 · Cited by 908
Bhattacharya, S., Datta, A., Berg, J. M., & Gangopadhyay, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844746 · Cited by 859
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Fully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Cited by
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Wireless chemical sensors and biosensors: A review
Kassal, P., Steinberg, M. D., & Steinberg, I. M. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.074 · Cited by 308
Privacy Protection for Blockchain-Based Healthcare IoT Systems: A Survey
Qi, M., Wang, Z., Han, Q.-L., Zhang, J., Chen, S., & Xiang, Y. (2024) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2022.106058 · Cited by 44
Metadata
- Authors
- Ahmadi, M. M., & Jullien, G. A.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2009-06
- Volume
- 3
- Issue
- 3
- Pages
- 169-180
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2164989510
- Cited by
- 266
- References
- 31
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring. https://app.cochat.ai/papers/10.1109/tbcas.2009.2016844
- The paper
- Ahmadi, M. M., & Jullien, G. A. (2009). A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2009.2016844
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.