Stochastic Model Predictive Control for Building HVAC Systems: Complexity and Conservatism
Abstract
This paper presents a stochastic model predictive control (SMPC) approach to building heating, ventilation, and air conditioning (HVAC) systems. The building HVAC system is modeled as a network of thermal zones controlled by a central air handling unit and local variable air volume boxes. In the first part of this paper, simplified nonlinear models are presented for thermal zones and HVAC system components. The uncertain load forecast in each thermal zone is modeled by finitely supported probability density functions (pdfs). These pdfs are initialized using historical data and updated as new data becomes available. In the second part of this paper, we present a SMPC design that minimizes expected energy cost and bounds the probability of thermal comfort violations. SMPC uses predictive knowledge of uncertain loads in each zone during the design stage. The complexity of a commercial building requires special handling of system nonlinearities and chance constraints to enable real-time implementation, minimize energy cost, and guarantee thermal comfort. This paper focuses on the tradeoff between computational tractability and conservatism of the resulting SMPC scheme. The proposed SMPC scheme is compared with alternative SMPC designs, and the effectiveness of the proposed approach is demonstrated by simulation and experimental tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
A Review of Deep Reinforcement Learning for Smart Building Energy Management
Yu, L., Qin, S., Zhang, M., Shen, C., Jiang, T., & Guan, X. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3078462 · Cited by 476
Ten Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Yao, Y., & Shekhar, D. K. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107952 · Cited by 447
Modeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411
Metadata
- Authors
- Ma, Y., Matusko, J., & Borrelli, F.
- Venue
- IEEE Transactions on Control Systems Technology
- Published
- 2015-01
- Volume
- 23
- Issue
- 1
- Pages
- 101-116
- ISSN
- 1063-6536 (ISSN-L)
- 1558-0865
- OpenAlex
- W2018386036
- Cited by
- 233
- References
- 0
- FWCI
- 25.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stochastic Model Predictive Control for Building HVAC Systems: Complexity and Conservatism. https://app.cochat.ai/papers/10.1109/tcst.2014.2313736
- The paper
- Ma, Y., Matusko, J., & Borrelli, F. (2015). Stochastic Model Predictive Control for Building HVAC Systems: Complexity and Conservatism. IEEE Transactions on Control Systems Technology. https://doi.org/10.1109/tcst.2014.2313736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.