Stochastic Model Predictive Control for Building HVAC Systems: Complexity and Conservatism
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
This paper presents a stochastic model predictive control (SMPC) approach to building heating, ventilation, and air conditioning (HVAC) systems. The building HVAC system is modeled as a network of thermal zones controlled by a central air handling unit and local variable air volume boxes. In the first part of this paper, simplified nonlinear models are presented for thermal zones and HVAC system components. The uncertain load forecast in each thermal zone is modeled by finitely supported probability density functions (pdfs). These pdfs are initialized using historical data and updated as new data becomes available. In the second part of this paper, we present a SMPC design that minimizes expected energy cost and bounds the probability of thermal comfort violations. SMPC uses predictive knowledge of uncertain loads in each zone during the design stage. The complexity of a commercial building requires special handling of system nonlinearities and chance constraints to enable real-time implementation, minimize energy cost, and guarantee thermal comfort. This paper focuses on the tradeoff between computational tractability and conservatism of the resulting SMPC scheme. The proposed SMPC scheme is compared with alternative SMPC designs, and the effectiveness of the proposed approach is demonstrated by simulation and experimental tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density Estimation for Statistics and Data Analysis
Silverman, B. W. (2018) · Routledge eBooks · doi:10.1201/9781315140919 · Cited by 15,796
Wächter, A., & Biegler, L. T. (2006) · Mathematical Programming · doi:10.1007/s10107-004-0559-y · Cited by 9,483
Density Estimation for Statistics and Data Analysis
(1986) · Springer eBooks · doi:10.1007/978-1-4899-3324-9 · Cited by 8,525
Chance-Constrained Programming
Charnes, A., & Cooper, W. W. (1959) · Management Science · doi:10.1287/mnsc.6.1.73 · Cited by 2,742
The Scenario Approach to Robust Control Design
Calafiore, G. C., & Campi, M. C. (2006) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2006.875041 · Cited by 1,150 · cited 1×
“Non-Gaussian and finitely supported disturbances have been studied in [8], [9], [11], [13], [29], and [30] in the context of SMPC.”
BackgroundModel Predictive Control for the Operation of Building Cooling Systems
Ma, Y., Borrelli, F., Hencey, B., Coffey, B., Bengea, S., & Haves, P. (2012) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2011.2124461 · Cited by 527
Self-citationMin-max control of constrained uncertain discrete-time linear systems
Bemporad, A., Borrelli, F., & Morari, M. (2003) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2003.816984 · Cited by 518
Self-citationPartial- and whole-body thermal sensation and comfort—Part II: Non-uniform environmental conditions
Arens, E., Zhang, H., & Huizenga, C. (2006) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2005.11.027 · Cited by 436 · cited 1×
“of thermal conform has been the subject of extensive study in [1] and [2].”
BackgroundOldewurtel, F., Parisio, A., Jones, C. N., Morari, M., Gyalistras, D., Gwerder, M., Stauch, V, Lehmann, B., & Wirth, K. (2010) · Proceedings of the 2010 American Control Conference · doi:10.1109/acc.2010.5530680 · Cited by 435 · cited 1×
“I. INTRODUCTION IN THE past years, there has been a renewed inter-est in modeling and predictive control for energy conversion, storage, and distribution in commercial buildings [3], [6], [18]–[22], [25]–[27], [32]–[35], [37]–[39].”
BackgroundReducing energy costs and peak electrical demand through optimal control of building thermal storage
Braun, J. E. (1990) · Cited by 434
Cited by
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
A Review of Deep Reinforcement Learning for Smart Building Energy Management
Yu, L., Qin, S., Zhang, M., Shen, C., Jiang, T., & Guan, X. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3078462 · Cited by 476
Ten Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Yao, Y., & Shekhar, D. K. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107952 · Cited by 447
Modeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411
Multi-Agent Deep Reinforcement Learning for HVAC Control in Commercial Buildings
Yu, L., Sun, Y., Xu, Z., Shen, C., Yue, D., Jiang, T., & Guan, X. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3011739 · Cited by 353
Stochastic linear Model Predictive Control with chance constraints – A review
Farina, M., Giulioni, L., & Scattolini, R. (2016) · Journal of Process Control · doi:10.1016/j.jprocont.2016.03.005 · Cited by 342
Zhang, Z., Chong, A., Pan, Y., Zhang, C., & Lam, K. P. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.07.029 · Cited by 339
Smarra, F., Jain, A., de Rubeis, T., Ambrosini, D., D’Innocenzo, A., & Mangharam, R. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.126 · Cited by 338
Thieblemont, H., Haghighat, F., Ooka, R., & Moreau, A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.010 · Cited by 194
Huang, H., Chen, L., & Hu, E. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.01.037 · Cited by 181
Data-driven methods for building control — A review and promising future directions
Maddalena, E. T., Lian, Y., & Jones, C. N. (2020) · Control Engineering Practice · doi:10.1016/j.conengprac.2019.104211 · Cited by 159
“In order to circumvent the subjectiveness of both the PMV and PPD indexes, the majority of authors as well as practitioners opt for simply defining temperature envelopes to be respected in each environment [Mantovani and Ferrarini, 2015, Ma et al., 2015, Ben-Nakhi and Mahmoud, 2017].”
Cox, S. J., Kim, D., Cho, H., & Mago, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.093 · Cited by 157
Economic MPC and real-time decision making with application to large-scale HVAC energy systems
Rawlings, J. B., Patel, N. R., Risbeck, M. J., Maravelias, C. T., Wenzel, M. J., & Turney, R. D. (2018) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2017.10.038 · Cited by 129
Kanellopoulos, D., Sharma, V. K., Panagiotakopoulos, T., & Kameas, A. (2023) · Electronics · doi:10.3390/electronics12112490 · Cited by 120
Metadata
- Authors
- Ma, Y., Matusko, J., & Borrelli, F.
- Venue
- IEEE Transactions on Control Systems Technology
- Published
- 2015-01
- Volume
- 23
- Issue
- 1
- Pages
- 101-116
- ISSN
- 1063-6536 (ISSN-L)
- 1558-0865
- OpenAlex
- W2018386036
- Cited by
- 233
- References
- 32
- FWCI
- 25.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.