Energy-Optimal Control of an Automotive Air Conditioning System for Ancillary Load Reduction
Abstract
The air conditioning (A/C) system is currently the largest ancillary load in passenger cars, with a significant impact on fuel economy and CO2 emissions. Considerable energy savings could be attained by simply adopting supervisory energy management algorithms that operate the A/C system to reduce power consumption of the compressor, while maintaining the cabin comfort requirements. This paper proposes a model-based approach to the design of a supervisory energy management strategy for automotive A/C systems. Starting from an energy-based model of the A/C system that captures the complex dynamics of the refrigerant in the heat exchangers and the compressor power consumption, a constrained multiobjective optimal control problem is formulated to jointly account for fuel consumption, cabin comfort, and system durability. The tradeoff between fuel economy, performance, and durability is analyzed by performing a Pareto analysis of a family of solutions generated using dynamic programming. A forward-looking optimal compressor clutch policy is then obtained by developing an original formulation of Pontryagin's minimum principle for hybrid dynamical systems. The simulation results demonstrate that the proposed control strategy allows for fuel economy improvement while retaining system performance and driver comfort.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Existing HVAC studies do not consider the large yearly variation of cabin thermal needs nor the reduced performances of heat pumps at very low temperatures.
“However, these studies do not consider the large yearly variation of the cabin thermal needs, nor the reduced performances of heat pumps at very low temperatures.”
From Flexible Simulation of an Electric Vehicle to Estimate the Impact of Thermal Comfort on the Energy Consumption (2022) · cites this paper as [29]
The control of a heat pump is much more complex than the presented control, because it is necessary to regulate the pressures of the heat exchangers, as well as the mass flow of the refrigerant.
“Indeed, the control of a heat pump is much more complex, because it is necessary to regulate the pressures of the heat exchangers, as well as the mass flow of the refrigerant [29].”
From Flexible Simulation of an Electric Vehicle to Estimate the Impact of Thermal Comfort on the Energy Consumption (2022) · cites this paper as [29]
Cites
Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers
Kim, M.-H., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00025-1 · Cited by 280 · cited 1× · see citing works
“The correlations to calculate the heat transfer coefficients adopted in this paper are specific to cross-flow compact heat exchangers with louvers and fins, and have been proposed in [25] and [26].”
Method
Flagged first, then by citations
Cited by
Sorted by citations
Ramsey, D., Bouscayrol, A., Boulon, L., Desreveaux, A., & Vaudrey, A. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3144526 · Cited by 39 · see citing works
- Authors
- Zhang, Q., Stockar, S., & Canova, M.
- Affiliations
- The Ohio State University (US)
- Venue
- IEEE Transactions on Control Systems Technology
- Published
- 2016-01
- Volume
- 24
- Issue
- 1
- Pages
- 67-80
- ISSN
- 1063-6536 (ISSN-L)
- 1558-0865
- OpenAlex
- W4230539994
- Cited by
- 42
- References
- 1
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 7 · 2019: 3 · 2018: 1 · 2017: 2 · 2016: 3
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Control Systems Technology (publishedVersion)
- Funders
- U.S. Department of Energy through Chrysler Group, LLC, Detroit, MI, USA (DE-EE0003347)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Automotive Engineering › Electric and Hybrid Vehicle Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- automotive air conditioning, compressor power consumption, fuel economy, CO2 emissions, cabin comfort, Pontryagin maximum principle, hybrid dynamical systems, Pareto analysis, multi-objective optimal control, dynamic programming, system durability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review