Accelerated insulation aging due to fast, repetitive voltages: A review identifying challenges and future research needs
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Although the adverse effects of using power electronic conversion on the insulation systems used in different apparatuses have been investigated, they are limited to low slew rates and repetitions. These results cannot be used for next-generation wide bandgap (WBG)-based conversion systems targeted to be fast (with a dv/dt up to 100 kV/ws) and operate at a high switching frequency up to 500 kHz. Frequency and slew rate are two of the most important factors of a voltage pulse, influencing the level of degradation of the insulation systems that are exposed to such voltage pulses. The paper reviews challenges concerning insulation degradation when benefitting from WBG-based conversion systems with the mentioned dv/dt and switching frequency values and identifies technical gaps and future research needs. The paper provides a framework for future research in dielectrics and electrical insulation design for systems under fast, repetitive voltage pluses originated by WBG-based conversion systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Wide Bandgap Power Semiconductor Devices
Millán, J., Godignon, P., Perpiñà, X., Pérez-Tomás, A., & Rebollo, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2268900 · Cited by 2,685 · cited 1×
“The main advantage of SiC is that it features a breakdown electric field nearly an order of magnitude higher than Si, as well as being capable of exceedingly fast commutation while exhibiting reduced conduction and switching losses and being able to operate at higher temperatures [6-8].”
BackgroundAnalysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors
Bonnett, A. H. (2002) · Proceedings of IEEE Pulp and Paper Industry Conference · doi:10.1109/papcon.1994.324506 · Cited by 206 · cited 1×
“Some papers investigated cable-motor sets and, therefore, included impedance mismatch issues in uneven distribution voltage issues due to fast-fronted surges [84, 99, 100].”
BackgroundAnalysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors
Bonnett, A. H. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.491488 · Cited by 193
Universal Induction Motor Model With Low-to-High Frequency-Response Characteristics
Mirafzal, B., Skibinski, G. L., Tallam, R. M., Schlegel, D. W., & Lukaszewski, R. A. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.904401 · Cited by 187 · cited 1×
“Initiated by [76-80], the multiconductor transmission line (MTL) model, which considers wave propagation within coils, has been developed as a lossy MTL model [81], non-linear MTL model [82], a finite element method (FEM) [81-83] or certain average techniques [84-86] to characterize different elements from the winding…”
MethodEffect of surge voltage risetime on the insulation of low-voltage machines fed by PWM converters
Melfi, M. J., Sung, A. M. J., Bell, S., & Skibinski, G. L. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.703971 · Cited by 174
Next Generation Integrated Power System: NGIPS Technology Development Roadmap
Doerry, N., & McCoy, K. (2007) · doi:10.21236/ada519753 · Cited by 155
Effect of rise time on PD pulse features under repetitive square wave voltages
Wang, P. W., Cavallini, A., Montanari, G. C., et al. (2013) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2013.6451364 · Cited by 150 · cited 2×
“Furthermore, neither in-depth (physical-based) explanation nor a model is presented for the test results [13-18].”
BackgroundInverter-Fed Drives: Which Motor Stators Are at Risk?
Stone, G. C., Campbell, S., & Tetreault, S. (2000) · IEEE Industry Applications Magazine · doi:10.1109/2943.863631 · Cited by 146 · cited 1×
“resulting in a forced outage of the drive system [71].”
BackgroundShip to Grid: Medium-Voltage DC Concepts in Theory and Practice
Reed, G. F., Grainger, B. M., Sparacino, A. R., & Mao, Z. (2012) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2012.2212613 · Cited by 137 · cited 2×
“After developing high frequency EMT models for all apparatuses of a power system benefitting from WBG-based conversion systems for various applications such as the medium voltage direct current (MVDC) system for future U.S. naval ships [101, 102], more-electric commercial aircraft, and all/hybrid electric aircraft con…”
BackgroundEffect of surge voltage risetime on the insulation of low voltage machines fed by PWM converters
Melfi, M. J., Sung, J., Bell, S., & Skibinski, G. L. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.643034 · Cited by 137
Cited by
Components of Electrical Power Systems in More and All-Electric Aircraft: A Review
Barzkar, A., & Ghassemi, M. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3174362 · Cited by 233
“Apart from that, high speed, high-frequency WBG-based drive systems are another potential threat to the insulation system which must carefully be taken into consideration when designing the aircraft insulation system [36, 37].”
BackgroundSelf-citation
Metadata
- Authors
- Ghassemi, M.
- Venue
- IEEE Transactions on Dielectrics and Electrical Insulation
- Published
- 2019-10
- Volume
- 26
- Issue
- 5
- Pages
- 1558-1568
- ISSN
- 1070-9878 (ISSN-L)
- 1558-4135
- OpenAlex
- W2978972067
- Cited by
- 164
- References
- 35
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerated insulation aging due to fast, repetitive voltages: A review identifying challenges and future research needs. https://app.cochat.ai/papers/10.1109/tdei.2019.008176
- The paper
- Ghassemi, M. (2019). Accelerated insulation aging due to fast, repetitive voltages: A review identifying challenges and future research needs. IEEE Transactions on Dielectrics and Electrical Insulation. https://doi.org/10.1109/tdei.2019.008176
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.