Accelerated insulation aging due to fast, repetitive voltages: A review identifying challenges and future research needs
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Although the adverse effects of using power electronic conversion on the insulation systems used in different apparatuses have been investigated, they are limited to low slew rates and repetitions. These results cannot be used for next-generation wide bandgap (WBG)-based conversion systems targeted to be fast (with a dv/dt up to 100 kV/ws) and operate at a high switching frequency up to 500 kHz. Frequency and slew rate are two of the most important factors of a voltage pulse, influencing the level of degradation of the insulation systems that are exposed to such voltage pulses. The paper reviews challenges concerning insulation degradation when benefitting from WBG-based conversion systems with the mentioned dv/dt and switching frequency values and identifies technical gaps and future research needs. The paper provides a framework for future research in dielectrics and electrical insulation design for systems under fast, repetitive voltage pluses originated by WBG-based conversion systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Wide Bandgap Power Semiconductor Devices
Millán, J., Godignon, P., Perpiñà, X., Pérez-Tomás, A., & Rebollo, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2268900 · Cited by 2,685 · cited 1×
“The main advantage of SiC is that it features a breakdown electric field nearly an order of magnitude higher than Si, as well as being capable of exceedingly fast commutation while exhibiting reduced conduction and switching losses and being able to operate at higher temperatures [6-8].”
BackgroundAnalysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors
Bonnett, A. H. (2002) · Proceedings of IEEE Pulp and Paper Industry Conference · doi:10.1109/papcon.1994.324506 · Cited by 206 · cited 1×
“Some papers investigated cable-motor sets and, therefore, included impedance mismatch issues in uneven distribution voltage issues due to fast-fronted surges [84, 99, 100].”
BackgroundAnalysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors
Bonnett, A. H. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.491488 · Cited by 193
Universal Induction Motor Model With Low-to-High Frequency-Response Characteristics
Mirafzal, B., Skibinski, G. L., Tallam, R. M., Schlegel, D. W., & Lukaszewski, R. A. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.904401 · Cited by 187 · cited 1×
“Initiated by [76-80], the multiconductor transmission line (MTL) model, which considers wave propagation within coils, has been developed as a lossy MTL model [81], non-linear MTL model [82], a finite element method (FEM) [81-83] or certain average techniques [84-86] to characterize different elements from the winding…”
MethodEffect of surge voltage risetime on the insulation of low-voltage machines fed by PWM converters
Melfi, M. J., Sung, A. M. J., Bell, S., & Skibinski, G. L. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.703971 · Cited by 174
Next Generation Integrated Power System: NGIPS Technology Development Roadmap
Doerry, N., & McCoy, K. (2007) · doi:10.21236/ada519753 · Cited by 155
Effect of rise time on PD pulse features under repetitive square wave voltages
Wang, P. W., Cavallini, A., Montanari, G. C., et al. (2013) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2013.6451364 · Cited by 150 · cited 2×
“Furthermore, neither in-depth (physical-based) explanation nor a model is presented for the test results [13-18].”
BackgroundInverter-Fed Drives: Which Motor Stators Are at Risk?
Stone, G. C., Campbell, S., & Tetreault, S. (2000) · IEEE Industry Applications Magazine · doi:10.1109/2943.863631 · Cited by 146 · cited 1×
“resulting in a forced outage of the drive system [71].”
BackgroundShip to Grid: Medium-Voltage DC Concepts in Theory and Practice
Reed, G. F., Grainger, B. M., Sparacino, A. R., & Mao, Z. (2012) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2012.2212613 · Cited by 137 · cited 2×
“After developing high frequency EMT models for all apparatuses of a power system benefitting from WBG-based conversion systems for various applications such as the medium voltage direct current (MVDC) system for future U.S. naval ships [101, 102], more-electric commercial aircraft, and all/hybrid electric aircraft con…”
BackgroundEffect of surge voltage risetime on the insulation of low voltage machines fed by PWM converters
Melfi, M. J., Sung, J., Bell, S., & Skibinski, G. L. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.643034 · Cited by 137
Efficiency Comparison Between Si-IGBT-Based Drive and GaN-Based Drive
Shirabe, K., Swamy, M. M., Kang, J.-K., Hisatsune, M., Wu, Y., Kebort, D., & Honea, J. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2290812 · Cited by 132 · cited 1×
“size and weight of the passive components such as output sine wave filters can be decreased [21, 22].”
BackgroundPEBB - power electronics building blocks, from concept to reality
Ericsen, T., Khersonsky, Y., Schugart, P., & Steimer, P. (2006) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp:20060063 · Cited by 124
Analysis of insulation failure modes in high power IGBT modules
Fabian, J.-H., Hartmann, S., & Hamidi, A. (2005) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2005.1518425 · Cited by 110 · cited 3×
“However, PD in a power electronic module is an ultra-low-light-level phenomenon and a very compact intensified CCD camera is needed to record the small light intensities emitted by electroluminescence effects as well as light caused by PD [38].”
BackgroundMethodOn the interpretation of some electrical aging and relaxation phenomena in solid dielectrics
Crine, J. ‐. (2005) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2005.1561789 · Cited by 109 · cited 2×
“polymer was introduced in [31-33]; thus, bonds will be broken, and the nanocavity will expand.”
BackgroundThe influence of repetitive square wave voltage parameters on enameled wire endurance
Wang, P., Cavallini, A., & Montanari, G. C. (2014) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2014.6832275 · Cited by 105 · cited 2×
“Furthermore, neither in-depth (physical-based) explanation nor a model is presented for the test results [13-18].”
BackgroundOutput Filters for PWM Drives with Induction Motors
Finlayson, P. T. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.644886 · Cited by 103 · cited 1×
“To address this issue, filters were proposed to increase the rise time of the surges impinging on the insulation system terminations [19, 20].”
BackgroundCharacteristics of PD under square wave voltages and their influence on motor insulation endurance
Wang, P. W., Cavallini, A., & Montanari, G. C. (2015) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2015.005158 · Cited by 89 · cited 1×
“Furthermore, neither in-depth (physical-based) explanation nor a model is presented for the test results [13-18].”
BackgroundEspino-Cortes, F. P., Cherney, E. A., & Jayaram, S. H. (2007) · IEEE Electrical Insulation Magazine · doi:10.1109/mei.2007.288451 · Cited by 80 · cited 1×
“Switching transients, especially for wind applications subjected to more frequent switching operations and earth fault are two transient phenomena that can lead to resonant overvoltages at the LV terminal of a transformer as well as inside HV and LV windings [105-111].”
BackgroundCharacterization of the voltage and electric field stresses in multi-cell solid-state transformers
Guillod, T., Huber, J., Ortiz, G., De, A., Franck, C. M., & Kolar, J. W. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954048 · Cited by 72 · cited 1×
“Thermal and electro-thermal models were developed to predict the temperature distribution inside the cable termination [120, 121, 123-125], particularly under square wave pulses [121, 123] with a good agreement with test results [124], reporting increase temperatures of up to 9-10°C as shown in Figure 6 for slip-over…”
MethodWang, P. W., Xu, H., Wang, J., Wang, W., & Cavallini, A. (2017) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2017.006268 · Cited by 66 · cited 1×
“Furthermore, neither in-depth (physical-based) explanation nor a model is presented for the test results [13-18].”
BackgroundElectrical Insulation Weaknesses in Wide Bandgap Devices
Ghassemi, M. (2018) · InTech eBooks · doi:10.5772/intechopen.77657 · Cited by 48 · cited 1×
“A thorough and in-depth review of PD measurements, failure analysis, and control in high-power IGBT modules has been done in [35, 36].”
BackgroundSelf-citationElectrical shielding of MV/MF transformers subjected to high dv/dt PWM voltages
Guillod, T., Krismer, F., & Kolar, J. W. (2017) · 2017 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2017.7931050 · Cited by 47
Power Electronics Building Block (PEBB) design based on 1.7 kV SiC MOSFET modules
Wang, J., Shen, Z., Cvetkovic, I., Mehrabadi, N. R., Marzoughi, A., Ohn, S., Yu, J., Xu, Y., Burgos, R. P., & Boroyevich, D. (2017) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2017.8069345 · Cited by 47 · cited 1×
“7 kV, 300-A SiC MOSFET phase-leg modules in an H-bridge configuration [9, 10].”
Geometrical Techniques for Electric Field Control in (Ultra) Wide Bandgap Power Electronics Modules
Ghassemi, M. (2018) · IEEE Electrical Insulation Conference (EIC) · doi:10.1109/eic.2018.8481085 · Cited by 45 · cited 1×
“Moreover, geometrical techniques [52] or applying nonlinear”
Self-citationStress grading materials for cable terminations under fast-rise time pulses
Espino-Cortes, F. P., Jayaram, S. H., & Cherney, E. A. (2006) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2006.1624289 · Cited by 44
Computation and analysis of dielectric losses in MV power electronic converter insulation
Guillod, T., Färber, R., Krismer, F., Franck, C. M., & Kolar, J. W. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854952 · Cited by 43 · cited 1×
“[126].”
The effect of inverter characteristics on partial discharge and life behavior of wire insulation
Montanari, G. C., & Seri, P. (2018) · IEEE Electrical Insulation Magazine · doi:10.1109/mei.2018.8300442 · Cited by 41 · cited 1×
“Furthermore, neither in-depth (physical-based) explanation nor a model is presented for the test results [13-18].”
BackgroundDesign of a SiC-based modular multilevel converter for medium voltage DC distriution system
Yu, J., Burgos, R. P., Mehrabadi, N. R., & Boroyevich, D. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7930735 · Cited by 38
Tousi, M. M., & Ghassemi, M. (2019) · IEEE International Workshop on Integrated Power Packaging (IWIPP) · doi:10.1109/iwipp.2019.8799101 · Cited by 34 · cited 1×
“Moreover, geometrical techniques [52] or applying nonlinear field dependent conductivity materials on high field regions [53-55] for electric field control in power electronic modules are only based on simulation results and have not been implemented in practical modules.”
BackgroundSelf-citationModeling of heat generated on stress grading coatings of motors fed by multilevel drives
Espino-Cortes, F. P., Gómez, P., & Ramírez, J. (2011) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2011.5976135 · Cited by 27 · cited 2×
“Degradation [113] and loss of resistivity and nonlinearity of the SG material [114] can be consequences of an increased temperature that in some cases can reach 55°C above that observed under sinusoidal 60/50 Hz frequency [115].”
BackgroundThe influence of square voltage waveforms on transformer insulation break down voltage
Kołtunowicz, T. N., Cavallini, A., Djairam, D., Montanari, G. C., & Smit, J. J. (2011) · IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) · doi:10.1109/ceidp.2011.6232593 · Cited by 26 · cited 2×
“A decreasing trend in PDIV after 1 kHz was also reported in [75].”
BackgroundOptical measurement of partial discharges in silicone gel under repetitive pulse voltage
Do, M. T., Augé, J.-L., & Lesaint, O. (2005) · International Symposium on Electrical Insulating Materials (ISEIM) · doi:10.1109/iseim.2005.193562 · Cited by 22 · cited 3×
“The optical technique is a promising method to localize PDs accurately in a power electronics module [38, 45, 46, 48, 50, 51].”
BackgroundMethodTransient potential measurement on stress grading under multi-level PWM
Nakamura, T., Kumada, A., Ikeda, H., Hidaka, K., Boggs, S. A., Tsuboi, Y., & Yoshimitsu, T. (2015) · IEEE Electrical Insulation Conference (EIC) · doi:10.1109/icacact.2014.7223536 · Cited by 17 · cited 1×
“voltage pulses originating from converter-fed drives, the stress grading (SG) system in a form-wound machine is another part that is adversely affected from such surges [112-119].”
BackgroundGhassemi, M., Cao, Y., & Chen, Q. (2018) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2018.006691 · Cited by 10 · cited 1×
“The author has established this approach in different applications [56-65] including gassolid and liquid-solid combination insulations.”
BackgroundSelf-citationPassivity Enforcement Using an Infeasible-Interior-Point Primal-Dual Method
Porkar, B., Vakilian, M., Iravani, R., & Shahrtash, S. M. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.922225 · Cited by 9 · cited 1×
“However, a higher order model usually leads to large passivity violations and, thus, complex methods such as infeasible-interior point primaldual methods [88] should be employed for passivity enforcement.”
Method
Cited by
Components of Electrical Power Systems in More and All-Electric Aircraft: A Review
Barzkar, A., & Ghassemi, M. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3174362 · Cited by 233
“Apart from that, high speed, high-frequency WBG-based drive systems are another potential threat to the insulation system which must carefully be taken into consideration when designing the aircraft insulation system [36, 37].”
BackgroundSelf-citation
Metadata
- Authors
- Ghassemi, M.
- Venue
- IEEE Transactions on Dielectrics and Electrical Insulation
- Published
- 2019-10
- Volume
- 26
- Issue
- 5
- Pages
- 1558-1568
- ISSN
- 1070-9878 (ISSN-L)
- 1558-4135
- OpenAlex
- W2978972067
- Cited by
- 164
- References
- 35
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.