Electrical shielding of MV/MF transformers subjected to high dv/dt PWM voltages
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The introduction of Medium-Voltage (MV) Silicon-Carbide (SiC) devices enables the usage of higher power converter operating voltages, switching frequencies, and commutation speeds. This implies that Medium-Frequency (MF) and High-Frequency (HF) transients are applied to passive components, and particularly to inductors and transformers. Together with the operation at medium voltage, this leads to challenging situations with respect to Common-Mode (CM) currents, parasitic resonances, insulation coordination, and EMI. The electrical field is the key parameter for the aforementioned effects. Therefore, this paper analyzes the electric field distribution (in the insulation, at the surface, and in the air) for a ±3.5kV/±400V, 50kHz, 25kW MV/MF transformer employed in a Solid-State Transformer (SST) demonstrator. For reducing the field, a suitable shield is designed. It is found that the shield drastically reduces the field at the surface of the transformer and in the air without increasing the losses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371 · cited 2×
“Compared to dual active bridge converters presented in [4], [9], this reduced switching speed limits the CM currents, the EMI emission, and the excitation of transformer resonances.”
BackgroundMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249
An actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135
Ortiz, G., Leibl, M., Kolar, J. W., & Apeldoorn, O. (2013) · 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527217 · Cited by 126 · cited 8×
“The increased switching frequency has a direct impact on the core losses (eddy currents and hysteresis) and winding losses (skin and proximity effects) [3].”
BackgroundMethodSelf-citation
Cited by
Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279030 · Cited by 111
Mocevic, S., Yu, J., Fan, B., Sun, K., Xu, Y., Stewart, J., Rong, Y., Song, H., Mitrovic, V., Yan, N., et al. (2022) · iEnergy · doi:10.23919/ien.2022.0001 · Cited by 88
Li, Z., Hsieh, Y.-H., Li, Q., Lee, F. C., & Ahmed, M. H. (2020) · 2020 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236384 · Cited by 71
Metadata
- Authors
- Guillod, T., Krismer, F., & Kolar, J. W.
- Venue
- 2017 IEEE Applied Power Electronics Conference and Exposition (APEC)
- Publisher
- IEEE
- Published
- 2017-03
- Pages
- 2502-2510
- OpenAlex
- W2614697073
- Cited by
- 47
- References
- 4
- FWCI
- 7.39
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical shielding of MV/MF transformers subjected to high dv/dt PWM voltages. https://app.cochat.ai/papers/10.1109/apec.2017.7931050
- The paper
- Guillod, T., Krismer, F., & Kolar, J. W. (2017). Electrical shielding of MV/MF transformers subjected to high dv/dt PWM voltages. 2017 IEEE Applied Power Electronics Conference and Exposition (APEC). https://doi.org/10.1109/apec.2017.7931050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.