Industrial Control System Network Intrusion Detection by Telemetry Analysis
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Until recently, industrial control systems (ICSs) used “air-gap” security measures, where every node of the ICS network was isolated from other networks, including the Internet, by a physical disconnect. Attaching ICS networks to the Internet benefits companies and engineers who use them. However, as these systems were designed for use in the air-gapped security environment, protocols used by ICSs contain little to no security features and are vulnerable to various attacks. This paper proposes an approach to detect the intrusions into network attached ICSs by measuring and verifying data that is transmitted through the network but is not inherently the data used by the transmission protocol-network telemetry. Using simulated PLC units, the developed IDS was able to achieve 94.3 percent accuracy when differentiating between machines of an attacker and engineer on the same network, and 99.5 percent accuracy when differentiating between attacker and engineer on the Internet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chandola, V., Banerjee, A., & Kumar, V. (2009) · ACM Computing Surveys · doi:10.1145/1541880.1541882 · Cited by 11,687 · cited 1×
“Unique intrusion detection implementations have been suggested.”
Guide to Industrial Control Systems (ICS) Security
Stouffer, K., Pillitteri, V., Lightman, S., Abrams, M., & Hahn, A. (2015) · doi:10.6028/nist.sp.800-82r2 · Cited by 1,377 · cited 1×
“Additionally, an attacker can perform data manipulations on the network to achieve S. Ponomarev is with the College of Engineering and Science, Louisiana Tech University, Ruston, LA 71272.”
MethodA Taxonomy of Cyber Attacks on SCADA Systems
Zhu, B., Joseph, A., & Sastry, S. (2011) · 2011 International Conference on Internet of Things and 4th International Conference on Cyber, Physical and Social Computing · doi:10.1109/ithings/cpscom.2011.34 · Cited by 458 · cited 1×
“To achieve this, telemetry-based IDSs need to monitor all packets traversing the ICS network, have a running average of the telemetry data, and be able to alert system engineers when anomalies in traffic are detected.”
BackgroundAccurate modeling of modbus/TCP for intrusion detection in SCADA systems
Goldenberg, N., & Wool, A. (2013) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2013.05.001 · Cited by 323 · cited 1×
“Sayegh et al. [15] proposed an IDS which uses temporal packet data to identify traffic anomalies.”
BackgroundA Multidimensional Critical State Analysis for Detecting Intrusions in SCADA Systems
Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., & Trombetta, A. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2099234 · Cited by 259
Cited by
Smart Cities: A Survey on Data Management, Security, and Enabling Technologies
Gharaibeh, A., Salahuddin, M. A., Hussini, S. J., Khreishah, A., Khalil, I., Guizani, M., & Al-Fuqaha, A. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2736886 · Cited by 628
A Survey on SCADA Systems: Secure Protocols, Incidents, Threats and Tactics
Pliatsios, D., Sarigiannidis, P., Lagkas, T., & Sarigiannidis, A. G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2987688 · Cited by 320
“Ponomarev and Atkison [92] proposed an IDS that utilizes network telemetry to detect cyber attacks.”
BackgroundHao, W., Yang, T., & Yang, Q. (2023) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2021.3073396 · Cited by 143
Current cyber-defense trends in industrial control systems
Rubio, J. E., Alcaraz, C., Roman, R., & Lopez, J. (2019) · Computers & Security · doi:10.1016/j.cose.2019.06.015 · Cited by 113
“via ICMP messages) of these parameters, it is possible to detect variations in the traffic patterns that are indicative of ongoing attacks [67], detect fake control devices [68], discover covert manipulations of the controller device code [69], and even deduce the CPU load of PLCs [70].”
BackgroundAtheeq, C., Sultana, R., Sabahath, S. A., & Mohammed, M. A. K. (2024) · Engineering, Technology & Applied Science Research · doi:10.48084/etasr.6969 · Cited by 18
Metadata
- Authors
- Ponomarev, S., & Atkison, T.
- Venue
- IEEE Transactions on Dependable and Secure Computing
- Published
- 2016-03-01
- Volume
- 13
- Issue
- 2
- Pages
- 252-260
- ISSN
- 1545-5971 (ISSN-L)
- OpenAlex
- W2295637543
- Cited by
- 147
- References
- 5
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Industrial Control System Network Intrusion Detection by Telemetry Analysis. https://app.cochat.ai/papers/10.1109/tdsc.2015.2443793
- The paper
- Ponomarev, S., & Atkison, T. (2016). Industrial Control System Network Intrusion Detection by Telemetry Analysis. IEEE Transactions on Dependable and Secure Computing. https://doi.org/10.1109/tdsc.2015.2443793
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.