Cited by 259Smart Grid Security and ResilienceNetwork Security and Intrusion DetectionArtificial Immune Systems Applications

A Multidimensional Critical State Analysis for Detecting Intrusions in SCADA Systems

Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., Trombetta, A.·2011·IEEE Transactions on Industrial Informatics

Abstract

A relatively new trend in Critical Infrastructures (e.g., power plants, nuclear plants, energy grids, etc.) is the massive migration from the classic model of isolated systems, to a system-of-systems model, where these infrastructures are intensifying their interconnections through Information and Communications Technology (ICT) means. The ICT core of these industrial installations is known as Supervisory Control And Data Acquisition Systems (SCADA). Traditional ICT security countermeasures (e.g., classic firewalls, anti-viruses and IDSs) fail in providing a complete protection to these systems since their needs are different from those of traditional ICT. This paper presents an innovative approach to Intrusion Detection in SCADA systems based on the concept of Critical State Analysis and State Proximity. The theoretical framework is supported by tests conducted with an Intrusion Detection System prototype implementing the proposed detection approach.

Integrity signals

Registry

Crossref · 10.1109/tii.2010.2099234

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • SCADA systems run over conventional operating systems and thus inherit vulnerabilities that can compromise the SCADA system.

    “SCADA systems run over conventional operating systems (OS), thus inheriting vulnerabilities which can compromise the SCADA system [10].”
  • Most SCADA systems remain in operation from eight to fifteen years.

    “The installation of SCADA systems is costly and time-consuming and most systems remain in operation from eight to fifteen years [10].”
  • The attack in 2000 on a sewage control system in Queensland, Australia, causing flooding with a million litres of sewage, was an act of a disgruntled employee.

    “The attack in 2000 on a sewage control system in Queensland, Australia [10], [42] causing flooding with a million litres of sewage, was an act of a disgruntled employee.”
  • Application of a software update resulted in automatic shutdown of a nuclear plant.

    “Application of a software update resulted in automatic shutdown of a nuclear plant [10].”
  • Stuxnet infiltrated the network mainly through USB sticks.

    “Stuxnet infiltrated the network [10], [16] mainly through USB sticks.”

Cited by

Sorted by citations

Authors
Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., & Trombetta, A.
Affiliations
  • University of Insubria (IT)
  • Joint Research Centre (IT)
Venue
IEEE Transactions on Industrial Informatics
Published
2011-05
Volume
7
Issue
2
Pages
179-186
ISSN
  • 1551-3203 (ISSN-L)
  • 1941-0050
OpenAlex
W2141050228
Cited by
259
References
0
Citations by year
2026: 8 · 2025: 6 · 2024: 9 · 2023: 10 · 2022: 14 · 2021: 15 · 2020: 25 · 2019: 27 · 2018: 31 · 2017: 18 · 2016: 25 · 2015: 25 · 2014: 20 · 2013: 13 · 2012: 8
FWCI
23.44
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Industrial Informatics (publishedVersion)
  • IrInSubria (University of Insubria) (submittedVersion)
  • Joint Research Centre (European Commission) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Security and Intrusion Detection
  • Physical Sciences › Engineering › Biomedical Engineering › Artificial Immune Systems Applications
Keywords
SCADA systems, intrusion detection, critical infrastructure security, industrial control systems, systems of systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review