Abstract

The paper presents a neuro-fuzzy-based perspective to the automation of diagnosis and location of stator-winding interturn short circuits in CSI-fed brushless dc motors. Performance of the drive under normal and short-circuit conditions are obtained through classical lumped-parameter network models. Waveforms of the electromagnetic torque and summation of phase voltages are monitored to develop two independent diagnostic algorithms. Diagnostic indices derived from the characteristic waveforms using discrete Fourier transform (DFT) lead to identifying the number of shorted turns. Fault location is achieved through a different set of indices extracted by the short-time Fourier transform (STFT). Adaptive neuro-fuzzy inference systems (ANFIS) are trained based on simulation results to automate the diagnostic process. ANFIS testing along with the good agreement between simulated and measured waveforms show the effectiveness of the proposed techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tec.2005.847976

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 13

  1. 10.1109/60.368345 · DOI · Paper page
  2. 10.1109/60.911400 · DOI · Paper page
  3. 10.1109/41.873216 · DOI · Paper page
  4. 10.1109/IAS.2000.881138 · doi:10.1109/ias.2000.881138
  5. 10.1109/TIA.2003.811784 · DOI · Paper page
  6. 10.1109/60.790920 · DOI · Paper page
  7. 10.1109/TEC.2003.811741 · DOI · Paper page
  8. 10.1109/TEC.2003.811739 · DOI · Paper page
  9. 10.1109/41.873207 · DOI · Paper page
  10. 10.1109/21.256541 · DOI · Paper page
  11. 10.1109/41.807988 · DOI · Paper page
  12. 10.1109/TAES.1980.309005 · DOI
  13. 10.1109/TIA.1982.4504052 · doi:10.1109/tia.1982.4504052

Cited by

See all 105

Metadata

Authors
Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W.
Venue
IEEE Transactions on Energy Conversion
Published
2005-06
Volume
20
Issue
2
Pages
253-259
ISSN
  • 0885-8969 (ISSN-L)
  • 1558-0059
OpenAlex
W2171233586
Cited by
105
References
0
FWCI
7.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A neuro-fuzzy approach to automatic diagnosis and location of stator inter-turn faults in CSI-fed PM brushless DC motors. https://app.cochat.ai/papers/10.1109/tec.2005.847976
The paper
Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2005). A neuro-fuzzy approach to automatic diagnosis and location of stator inter-turn faults in CSI-fed PM brushless DC motors. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2005.847976

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.