Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips
Abstract
The use of doubly fed induction generators (DFIGs) in large wind turbines has become quite common over the last few years. These machines provide variable speed and are driven with a power converter which is sized for a small percentage of the turbine-rated power. A drawback of the DFIG is that it is very sensitive to grid disturbances, especially to voltage dips. However, the operation of the machine in these situations has only been studied in the literature by means of simulations. This paper develops a theoretical analysis of the dynamic behavior of the induction machine during three-phase voltage dips. The proposed analysis contributes to understanding the causes of the problem and represents a very useful tool to improve the existing solutions and propose new alternatives. Experimental results are in good agreement with those obtained theoretically and validate the proposed analysis.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
DFIG-based WECS is the most widely adopted because of its variable speed, constant frequency operation, and small size with high MVA ratings.
“There are different types of WECSs in the market; however, only the WECS based on doubly fed induction generator (DFIG) is the most widely adopted because of its variable speed, constant frequency operation and small size with high MVA ratings [129].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [129]
Cited by
Sorted by citations
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339 · see citing works
“Due to the PQ issues that were explained in [130], [131], and the stepping up of the voltage which requires a large conventional transformer that is unacceptable; accordingly, SST has a huge potential in wind as well related applications [65].”
Background
- Authors
- LÓpez, J., Sanchis, P., Roboam, X., & Marroyo, L.
- Affiliations
- Universidad Pública de Navarra (UPNA) (ES)
- Centre National de la Recherche Scientifique (FR)
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2007-09
- Volume
- 22
- Issue
- 3
- Pages
- 709-717
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2136512037
- Cited by
- 550
- References
- 0
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 9 · 2023: 13 · 2022: 19 · 2021: 22 · 2020: 30 · 2019: 31 · 2018: 44 · 2017: 38 · 2016: 43 · 2015: 61 · 2014: 42 · 2013: 52 · 2012: 34
- FWCI
- 19.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Energy Conversion (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- doubly fed induction generator, grid disturbances, wind turbines, dynamic behavior, induction motor, power converters, variable speed operation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review