Effect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid

Muljadi, Eduard, Butterfield, C. P., Parsons, Brian, Ellis, Abraham·2007·IEEE Transactions on Energy Conversion

Abstract

In this paper, we illustrate the effect of adding a hypothetical 100-MW doubly fed induction generator (DFIG) wind power plant to a weak transmission system. The effects of various wind plant load factors (100, 60 and 25% of nameplate rating) are investigated. System performance is compared to a 100-MW conventional synchronous generator interconnected at the same location. The conventional generator is installed some distance away. The simulations demonstrated that DFIG generators provide a good damping performance under these conditions. These results support the conclusion that modern wind power plants, equipped with power electronics and low-voltage ride-through capability, can be interconnected to weak power grids without reducing stability. To conduct the studies, we selected an area of the Western Electricity Coordinating Council power system that is electrically far from major generation centers and is weakly connected to the bulk transmission system. The area contains large motor loads. We observed the dynamic response of large motors in the vicinity, especially their ability to ride through fault events. The studies were conducted using positive sequence phasor time-domain analysis

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tec.2006.889602

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Muljadi, E., Butterfield, C. P., Parsons, B., & Ellis, A.
Venue
IEEE Transactions on Energy Conversion
Published
2007-03
Volume
22
Issue
1
Pages
29-36
ISSN
0885-8969 (ISSN-L)
OpenAlex
W2109075053
Cited by
250
References
0
FWCI
13.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.