Integration of Large Photovoltaic and Wind System by Means of Smart Transformer
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Large renewable energy systems, e.g., photovoltaic and wind turbine, are connected to grid, which is usually weak, with long lines. This degrades power system stability and reliability. Additionally, the magnetic characteristic of a conventional power transformer (CPT) implies a slow dynamic and leads to grid current harmonic too high when wind speed is low and irradiance is weak. This paper proposes a parallel connection of a solid-state transformer-based smart transformer and a CPT to not only reduce the power rating, but also to support the voltage amplitude and improve the grid current quality. The simulation and experimental results clearly verify the correctness and feasibility of the proposed strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The application of SST in solar PV can also be found in [55], [122] where SST with solar PV brings many benefits, such as reduced size and weight, enhanced reliability, easier maintenance, voltage amplitude improvement the grid current quality enhancement.”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [55]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772 · cited 1×
“The solid-state transformer (SST) has been applied for traction purpose by ABB, SIEMENS, ALSTOM, due to the advantages of low volume and weight [21-24].”
MethodLiu, X., Aichhorn, A., Liu, L., & Li, H. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2177501 · Cited by 486
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control
Zhang, L., Harnefors, L., & Nee, H.-P. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2047875 · Cited by 452
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445 · cited 1×
“The smart transformer (ST) [27], [28], instead, aims to provide ancillary services to the distribution grid [28]–[32], more than simply adapting the voltage level from MV to low voltage (LV) grids, like in the SST case.”
BackgroundSelf-citationEffect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid
Muljadi, E., Butterfield, C. P., Parsons, B., & Ellis, A. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889602 · Cited by 250
Qiao, W., Harley, R. G., & Venayagamoorthy, G. K. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2001456 · Cited by 217
Liu, L., Li, H., Xue, Y., & Liu, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2333004 · Cited by 212
Mitra, P., Zhang, L., & Harnefors, L. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2273979 · Cited by 165
Research works printed but not linked: 1
- R. Piwko, N. Miller, J. Gasca, X. Yuan, R. Dai, J. Lyons, "Integrating large wind farms into weak power grid with long transmission lines" in Proc. IEEE IPEMC 2006, pp. 1-7.
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“The application of SST in solar PV can also be found in [55], [122] where SST with solar PV brings many benefits, such as reduced size and weight, enhanced reliability, easier maintenance, voltage amplitude improvement the grid current quality enhancement.”
BackgroundPower system resilience and strategies for a sustainable infrastructure: A review
Mohanty, A., Ramasamy, A. K., Verayiah, R., Bastia, S., Dash, S. S., Cüce, E., Khan, T. M. Y., & Soudagar, M. E. M. (2024) · Alexandria Engineering Journal · doi:10.1016/j.aej.2024.06.092 · Cited by 154
Ruiz, F., Pérez, M. A., Espinosa, J. R., Gajowik, T., Styński, S., & Malinowski, M. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2950436 · Cited by 144
A review on solid-state transformer: A breakthrough technology for future smart distribution grids
Mishra, D. K., Ghadi, M. J., Li, L., Hossain, M. J., Zhang, J., Ray, P. K., & Mohanty, A. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107255 · Cited by 130
A detailed review of power system resilience enhancement pillars
Mishra, D. K., Eskandari, M., Abbasi, M. H., Sanjeevikumar, P., Zhang, J., & Li, L. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110223 · Cited by 80
Metadata
- Authors
- Zhu, R., De Carne, G., Deng, F., & Liserre, M.
- Affiliations
- Christian-Albrechts-Universität zu Kiel (DE)
- Southeast University (CN)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-11
- Volume
- 64
- Issue
- 11
- Pages
- 8928-8938
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2611380482
- Cited by
- 71
- References
- 36
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 7 · 2023: 3 · 2022: 4 · 2021: 8 · 2020: 15 · 2019: 14 · 2018: 9 · 2017: 5
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
- macau.uni-kiel.de
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion, other-oa)
- Funders
- European Commission (2007–2013, FP/2007-2013)/ERC, FP/2007/2013)
- FP7 Ideas: European Research Council (616344)
- Topics
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- solid-state transformer, photovoltaic systems, wind turbines, grid integration, parallel connection, grid current quality, harmonic compensation, weak grid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integration of Large Photovoltaic and Wind System by Means of Smart Transformer. https://app.cochat.ai/papers/10.1109/tie.2017.2701758
- The paper
- Zhu, R., De Carne, G., Deng, F., & Liserre, M. (2017). Integration of Large Photovoltaic and Wind System by Means of Smart Transformer. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2701758
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.