This paper describes ramp rate control of a photovoltaic (PV) generator with an electric double-layer capacitor. The capacitor absorbs rapid fluctuations of PV generation, and allows the generator to change its output at a limited ramp rate. The output is mainly determined by a moving average of the PV generation, but the capacitor voltage is also counted to keep the voltage at a specified value, and accordingly, to make the capacitor small. An expression for the capacitor size is derived. The feedback gain of the capacitor voltage is also examined to maintain enough energy storage in the capacitor. Some experiments are executed to demonstrate and validate the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photovoltaic and solar power forecasting for smart grid energy management
Wan, C., Zhao, J., Song, Y., Xu, Z., Lin, J., & Hu, Z. (2015) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2015.00046 · Cited by 654
(2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2304951 · Cited by 332
Metadata
- Authors
- Kakimoto, N., Satoh, H., Takayama, S., & Nakamura, K.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2009-06
- Volume
- 24
- Issue
- 2
- Pages
- 465-473
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2144073697
- Cited by
- 194
- References
- 0
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ramp-Rate Control of Photovoltaic Generator With Electric Double-Layer Capacitor. https://app.cochat.ai/papers/10.1109/tec.2008.2001580
- The paper
- Kakimoto, N., Satoh, H., Takayama, S., & Nakamura, K. (2009). Ramp-Rate Control of Photovoltaic Generator With Electric Double-Layer Capacitor. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2008.2001580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.