Cited by 104Electric Motor Design and AnalysisSensorless Control of Electric MotorsMachine Fault Diagnosis Techniques

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors

Cintron-Rivera, Jorge G., Foster, Shanelle N., Strangas, Elias G.·2015·IEEE Transactions on Energy Conversion

Abstract

This study presents a method to mitigate and alleviate the effects produced by a turn-to-turn short in a fault tolerant permanent magnet synchronous motor with single-layer concentrated windings. The rotor magnets are capable of inducing a high voltage across the fault contact point; this voltage has the potential to generate a high circulating current that promotes the rapid propagation of the fault due to the thermal stress created by the increased localized fault power losses. The scope of this study is for applications where postfault operation is desired, even if it means operating at reduced power capacity and lower speeds. Upon quick detection of a fault, the proposed technique can be used to decelerate the propagation of the fault and extend the machine's postfault life span. The technique consists of a magnetic field-weakening strategy at speeds below nominal, to reduce the voltage induced in the faulted portion. The concept is validated through finite element analysis, modeling, and experimental data. It is demonstrated that the proposed technique reduces the fault current magnitude and winding temperature.

Overview

Integrity signals

Registry

Crossref · 10.1109/tec.2014.2360813

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Research works printed but not linked: 2

  1. 0, Theory and Design of Fractional-Slot PM Machines
  2. 10.1109/ICPE.2011.5944430 · DOI

Cited by

Sorted by citations

Metadata

Authors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G.
Affiliations
Michigan State University (US)
Venue
IEEE Transactions on Energy Conversion
Published
2015-06
Volume
30
Issue
2
Pages
465-475
ISSN
  • 0885-8969 (ISSN-L)
  • 1558-0059
OpenAlex
W2005580246
Cited by
104
References
41
Citations by year
2025: 12 · 2024: 13 · 2023: 9 · 2022: 14 · 2021: 11 · 2020: 7 · 2019: 11 · 2018: 11 · 2017: 5 · 2016: 6 · 2015: 5
FWCI
2.83
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Energy Conversion (publishedVersion)
Funders
  • National Science Foundation (EECS-1102316)
  • Predoctoral Fellowship Project
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
Keywords
turn-to-turn faults, permanent magnet synchronous motor, fault tolerance, circulating current, fault propagation, winding temperature, fault current reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review