The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Abstract
This study presents a method to mitigate and alleviate the effects produced by a turn-to-turn short in a fault tolerant permanent magnet synchronous motor with single-layer concentrated windings. The rotor magnets are capable of inducing a high voltage across the fault contact point; this voltage has the potential to generate a high circulating current that promotes the rapid propagation of the fault due to the thermal stress created by the increased localized fault power losses. The scope of this study is for applications where postfault operation is desired, even if it means operating at reduced power capacity and lower speeds. Upon quick detection of a fault, the proposed technique can be used to decelerate the propagation of the fault and extend the machine's postfault life span. The technique consists of a magnetic field-weakening strategy at speeds below nominal, to reduce the voltage induced in the faulted portion. The concept is validated through finite element analysis, modeling, and experimental data. It is demonstrated that the proposed technique reduces the fault current magnitude and winding temperature.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The proposed technique can be used to slow down the damage spreading out and extend the service life of the machine after a failure.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [329]
In the citing paper
“This method consists in a field-weakening strategy at speeds below nominal, to reduce the voltage induced in the faulted part of the winding.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [329]
Citations
Cites
Electric Motor Drives: Modeling, Analysis, and Control
Krishnan, R. (2001) · Cited by 1,340
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Identification of Machine Parameters of a Synchronous Motor
Rahman, K. M., & Hiti, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.844379 · Cited by 276
IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults
Welchko, B. A., Jahns, T. M., Soong, W. L., et al. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811746 · Cited by 210
Control Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 202
Parameter Estimation for Condition Monitoring of PMSM Stator Winding and Rotor Permanent Magnets
Liu, K., Zhu, Z. Q., & Stone, D. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2238874 · Cited by 196
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Cheng, S., Zhang, P., & Habetler, T. G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064276 · Cited by 152
Jahns, T. M., & Caliskan, V. A. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.806049 · Cited by 147
Innovative remedial strategies for inverter faults in IPM synchronous motor drives
Bianchi, N., Bolognani, S., Zigliotto, M., et al. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.808334 · Cited by 145
Gu, B.-G., Choi, J., & Jung, I.-S. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2265400 · Cited by 133
Dynamic Modeling and Control for SPMSMs With Internal Turn Short Fault
Jeong, I., Hyon, B. J., & Nam, K. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2222049 · Cited by 129
Analytical Prediction of the Short-Circuit Current in Fault-Tolerant Permanent-Magnet Machines
Sun, Z., Wang, J., Howe, D., & Jewell, G. W. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005019 · Cited by 121
Enhanced Optimal Torque Control of Fault-Tolerant PM Machine Under Flux-Weakening Operation
Sun, Z., Wang, J., Jewell, G. W., & Howe, D. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029517 · Cited by 120
Fault-Tolerant Torque Control of BLDC Motors
Aghili, F. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2060361 · Cited by 78
Kim, K., Choi, D.-U., Gu, B.-G., & Jung, I.-S. (2010) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0183 · Cited by 71
Welchko, B. A., Lipo, T. A., Jahns, T. M., et al. (2003) · IEEE International Electric Machines and Drives Conference (IEMDC) · doi:10.1109/iemdc.2003.1211315 · Cited by 65
An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60
Experimentally Validated Dynamic Fault Model for PMSM with Stator Winding Inter-Turn Fault
Vaseghi, B., Nahid‐Mobarakeh, B., Takorabet, N., & Meibody‐Tabar, F. (2008) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/08ias.2008.24 · Cited by 57
Uncontrolled Generation in Interior Permanent-Magnet Machines
Liaw, C.-Z., Soong, W. L., Welchko, B. A., et al. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.851557 · Cited by 49
(2007) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2007.4544200 · Cited by 44
Implications of shorted turn faults in bar wound PM machines
Mitcham, A. J., Antonopoulos, G., & Cullen, J. J. A. (2004) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20040686 · Cited by 43
A simplified characterization method including saturation effects for permanent magnet Machines
Cintron-Rivera, J. G., Babel, A. S., Montalvo-Ortiz, E. E., et al. (2012) · doi:10.1109/icelmach.2012.6349974 · Cited by 40
Self-citationInductance Calculations in Permanent-Magnet Motors Under Fault Conditions
Leboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., et al. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2197402 · Cited by 40
Estimating Permanent-Magnet Motor Parameters Under Inter-Turn Fault Conditions
Leboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., et al. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2177642 · Cited by 38
Wu, Q. H., & Nandi, S. (2008) · Conference record · doi:10.1109/08ias.2008.25 · Cited by 38
Back-EMF Based Detection of Stator Winding Inter-turn Fault for PM Synchronous Motor Drives
Boileau, T., Nahid‐Mobarakeh, B., & Meibody‐Tabar, F. (2007) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2007.4544105 · Cited by 36
Welchko, B. A., Jahns, T. M., & Lipo, T. A. (2004) · PESC record · doi:10.1109/pesc.2004.1355448 · Cited by 32
Permanent magnets synchronous machines faults detection and identification
Vinson, G., Combacau, M., Prado, T., & Ribot, P. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6389265 · Cited by 29
Jahns, T. M. (2002) · Conference record · doi:10.1109/ias.1998.732333 · Cited by 22
A dynamic modeling and a fault detection scheme of a PMSM under an inter turn short
Gu, B.-G., Choi, J., & Jung, I.-S. (2012) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2012.6422784 · Cited by 17
Design and control of fault-tolerant permanent magnet machines
Mohammadpour, A., Gandhi, A., & Parsa, L. (2013) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2013.6525171 · Cited by 16
Inter-turn fault analysis of IPM type BLDC motor using fault impedance modeling
Kim, K., Hur, J., & Kang, G.-H. (2011) · doi:10.1109/icpe.2011.5944430 · Cited by 16
Stator winding inter-turn fault detection using control voltages demodulation
Boileau, T., Leboeuf, N., Nahid‐Mobarakeh, B., & Meibody‐Tabar, F. (2012) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2012.6243477 · Cited by 15
Vector controlled permanent magnet synchronous motor (PMSM) drive with stator turn fault
Hadef, M., Mékidèche, M. R., & Djerdir, A. (2010) · doi:10.1109/icelmach.2010.5608104 · Cited by 13
Xiao, Z., & Fang, H. (2011) · doi:10.1109/iccase.2011.5997721 · Cited by 11
Parametric sensitivity in the analysis and control of permanent magnet synchronous machines
Babel, A. S., Foster, S. N., Cintron-Rivera, J. G., et al. (2012) · doi:10.1109/icelmach.2012.6350003 · Cited by 10
Self-citationFault Types and Mitigation Techniques of PMAC Machines
Neely, J., & Strangas, E. G. (2006) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2006.252170 · Cited by 6
Self-citationInter-turn stator winding fault detection in PMSM using magnitude of reactive power
Taghipour‐Gorjikolaie, M., Razavi, S. M., Shamsinejad, M. A., et al. (2011) · doi:10.1109/iccaie.2011.6162141 · Cited by 5
Research works printed but not linked: 2
- 0, Theory and Design of Fractional-Slot PM Machines
- 10.1109/ICPE.2011.5944430 · DOI
Cited by
Sorted by citations
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Wang, B., Wang, J., Griffo, A., & Huang, L. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2908595 · Cited by 33
Metadata
- Authors
- Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G.
- Affiliations
- Michigan State University (US)
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2015-06
- Volume
- 30
- Issue
- 2
- Pages
- 465-475
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2005580246
- Cited by
- 104
- References
- 41
- Citations by year
- 2025: 12 · 2024: 13 · 2023: 9 · 2022: 14 · 2021: 11 · 2020: 7 · 2019: 11 · 2018: 11 · 2017: 5 · 2016: 6 · 2015: 5
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Energy Conversion (publishedVersion)
- Funders
- National Science Foundation (EECS-1102316)
- Predoctoral Fellowship Project
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- turn-to-turn faults, permanent magnet synchronous motor, fault tolerance, circulating current, fault propagation, winding temperature, fault current reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review