The DOI matches its Crossref record.
Adjusting Synchronverter Dynamic Response Speed via Damping Correction Loop
Abstract
This paper proposes to augment the conventional synchronverter control scheme with an auxiliary loop to freely adjust the dynamic response speed. This loop is dubbed as adamping correction loopsince its form and function are reminiscent of the damping component in the classical synchronous generator model. Central to the proposed auxiliary loop is the creation of an additional tuneable parameter that allows for unrestricted adjustment of the system damping ratio without affecting the steady-state frequency droop characteristic, which is an improvement over the conventional synchronverter design. In the proposed method, relevant parameters are analytically tuned and active- and reactive-power coupling effects are reduced when operating with increased response speed. The dynamic response and robustness of the approach are verified via extensive small-signal analysis. Furthermore, time-domain simulations highlight the advantages of the proposed method over existing ones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Virtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Research Roadmap on Grid-Forming Inverters
Lin, Y., Eto, J., Johnson, B., Flicker, J., Lasseter, R., Villegas Pico, H., Seo, G.-S., Pierre, B., & Ellis, A. (2020) · doi:10.2172/1721727 · Cited by 419
Metadata
- Authors
- Dong, S., & Chen, Y. C.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2017-06
- Volume
- 32
- Issue
- 2
- Pages
- 608-619
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2563156639
- Cited by
- 234
- References
- 0
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adjusting Synchronverter Dynamic Response Speed via Damping Correction Loop. https://app.cochat.ai/papers/10.1109/tec.2016.2645450
- The paper
- Dong, S., & Chen, Y. C. (2017). Adjusting Synchronverter Dynamic Response Speed via Damping Correction Loop. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2016.2645450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.