Polyimide-Enhanced Stretchable Interconnects: Design, Fabrication, and Characterization
The DOI matches its Crossref record.
Abstract
This paper discusses the optimization of a stretchable electrical interconnection between integrated circuits in terms of stretchability and fatigue lifetime. The interconnection is based on Cu stripes embedded in a polyimide-enhanced (PI-enhanced) layer. Design-of-experiment (DOE) methods and finite-element modeling were used to obtain an optimal design and to define design guidelines, concerning both stripe and layer dimensions and material selection. Stretchable interconnects with a PI-enhanced layer were fabricated based on the optimized design parameters and tested. In situ experimental observations did validate the optimal design. Statistical analysis indicated that the PI width plays the most important role among the different design parameters. By increasing the PI width, the plastic strain in the Cu stripes is reduced, and thus, the stretchability and fatigue lifetime of the system is increased. The experimental results demonstrate that the PI-enhanced stretchable interconnect enables elongations up to 250% without Cu rupture. This maximum elongation is two times larger than the one in samples without PI enhancement . Moreover, the fatigue life at 30% elongation is 470 times higher.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Materials for stretchable electronics
Wagner, S., & Bauer, S. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.37 · Cited by 449
Harris, K. D., Elias, A. L., & Chung, H.-J. (2016) · Journal of Materials Science · doi:10.1007/s10853-015-9643-3 · Cited by 403
“The greatest merit of this approach is that chip reliability under severe operating conditions has already been established, and thus only the resilience of the interconnects requires verification [358].”
BackgroundZhang, Y., Wang, S., Li, X., Fan, J. A., Xu, S., Song, Y. M., Choi, K., Yeo, W., Lee, W., Nazaar, S. N., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201302957 · Cited by 354
Wearable Soft Technologies for Haptic Sensing and Feedback
Yin, J., Hinchet, R., Shea, H., & Majidi, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007428 · Cited by 325
Recent Advances in Stretchable and Transparent Electronic Materials
McCoul, D., Hu, W., Gao, M., Mehta, V., & Pei, Q. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201500407 · Cited by 293
Metadata
- Authors
- Hsu, Y.-Y., Gonzalez, M., Bossuyt, F., Vanfleteren, J., & De Wolf, I.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2011-08
- Volume
- 58
- Issue
- 8
- Pages
- 2680-2688
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2146578241
- Cited by
- 104
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyimide-Enhanced Stretchable Interconnects: Design, Fabrication, and Characterization. https://app.cochat.ai/papers/10.1109/ted.2011.2147789
- The paper
- Hsu, Y.-Y., Gonzalez, M., Bossuyt, F., Vanfleteren, J., & De Wolf, I. (2011). Polyimide-Enhanced Stretchable Interconnects: Design, Fabrication, and Characterization. IEEE Transactions on Electron Devices. https://doi.org/10.1109/ted.2011.2147789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.