Study and Analysis of the Effects of SiGe Source and Pocket-Doped Channel on Sensing Performance of Dielectrically Modulated Tunnel FET-Based Biosensors
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Dielectrically modulated tunnel FET (DMTFET)-based biosensors show higher sensitivity but lower subthreshold current compared with their dielectrically modulated FET counterpart. In this context, the effect of use of silicon-germanium (SiGe) source and n+-pocket-doped channel is investigated with the help of extensive device-level simulations. This paper explores the underlying physics of germanium composition variation in the source region, and doping concentration variation in n+-pocket region, from the perspective of biomolecule conjugation. The effects of source bandgap and tunneling length over the band-to-band tunneling component have been analyzed, and, subsequently, the sensing performance of DMTFETs has been estimated. The results show that SiGe-source DMTFET has significant superiority over n+-pocket DMTFET for attaining higher subthreshold current level while retaining acceptable sensitivity. Such sensitivity-current optimization has been studied for different gate and drain biases, and the suitable biasing range of operation has been indicated. In addition, the relative efficiency of SiGe source and n+-pocket-doped channel has been studied under different biomolecule sample specifications. Finally, the influence of trap-assisted tunneling on DMTFET sensing performance has been analyzed, and the comparative role of SiGe source and n+pocket has also been indicated in this context.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 2×
“The other benefits of using such FET-based biosensors are the scope of on-chip integration, dimensional compatibility with different biological species, and so on [2], [3].”
BackgroundSubthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Narang, R., Reddy, K. V. S., Saxena, M., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2208115 · Cited by 308 · cited 5×
“Typically, the DMFET operates within a subthreshold current range of 1 × 10−6–1 × 10−2 μA, whereas the DMTFET operates in the range of 1 × 10−9–1 × 10−7 μA [11]–[13], [21].”
BackgroundMethodInfluentialDielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor
Kannan, N., & Kumar, M. J. (2013) · IEEE Electron Device Letters · doi:10.1109/led.2013.2283858 · Cited by 161
Cited by
Performance Assessment of A Novel Vertical Dielectrically Modulated TFET-Based Biosensor
Verma, M., Tirkey, S., Yadav, S., Sharma, D., & Yadav, D. S. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2732820 · Cited by 276
Wangkheirakpam, V. D., Bhowmick, B., & Pukhrambam, P. D. (2020) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2020.2969206 · Cited by 199
Metadata
- Authors
- Kanungo, S., Chattopadhyay, S., Gupta, P. S., Sinha, K., & Rahaman, H.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2016-06
- Volume
- 63
- Issue
- 6
- Pages
- 2589-2596
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2345576772
- Cited by
- 243
- References
- 4
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.