CoChat

The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.

Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor

Open access
Kannan, N., Kumar, M. Jagadesh · 2013 · IEEE Electron Device Letters

Abstract

In this letter, we propose a dielectric-modulated impact-ionization MOS (DIMOS) transistor-based sensor for application in label-free detection of biomolecules. Numerous reports exist on the experimental demonstration of nanogap-embedded field effect transistor-based biosensors, but an impact-ionization MOS (I-MOS)-based biosensor has not been reported previously. The concept of a dielectric-modulated I-MOS-based biosensor is presented in this letter based on technology computer-aided design simulation study. The results show a high sensitivity to the presence of biomolecules even at small channel lengths. In addition, a low variability of the sensitivity to the charges on the biomolecule is observed. The high sensitivity, dominance of dielectric-modulation effects, and operation at even small channel lengths make the DIMOS biosensor a promising alternative for CMOS-based sensor applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/led.2013.2283858

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Research works printed but not linked: 3

  1. 10.1109/ted.2004.841345(410 · doi:10.1109/ted.2004.841345(410
  2. mayer, 2006, Co-integration of 2 mV/dec subthreshold slope impact ionization MOS (I-MOS) with CMOS, Proc 36th ESSDERC, 303
  3. 2000, Atlas User's Manual Device Simulation Software

Cited by

See all 163

Metadata

Authors
Kannan, N., & Kumar, M. J.
Affiliations
Indian Institute of Technology Delhi (IN)
Venue
IEEE Electron Device Letters
Published
2013-12
Volume
34
Issue
12
Pages
1575-1577
ISSN
  • 0741-3106 (ISSN-L)
  • 1558-0563
OpenAlex
W2137015982
Cited by
161
References
14
Citations by year
2026: 3 · 2025: 16 · 2024: 25 · 2023: 15 · 2022: 12 · 2021: 22 · 2020: 18 · 2019: 8 · 2018: 12 · 2017: 11 · 2016: 8 · 2015: 10 · 2014: 1
FWCI
3.80
Type
journal article
Language
en
Open access
Locations
  • IEEE Electron Device Letters (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
dielectric modulation, label-free biosensor, biomolecule detection, charge sensitivity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor. https://app.cochat.ai/papers/10.1109/led.2013.2283858
The paper
Kannan, N., & Kumar, M. J. (2013). Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor. IEEE Electron Device Letters. https://doi.org/10.1109/led.2013.2283858

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.