Denial of Service Attack on Tie-Line Bias Control in a Power System With PV Plant
The DOI matches its Crossref record.
Abstract
The use of synchrophasor networks consisting of phasor measurement units (PMUs) makes it possible to monitor, analyzes, and control the electric power grid in real-time. PMU measurements of frequencies, currents, voltages, and phase angles are transmitted to system control centers through synchrophasor networks. Delayed or missing measurements from PMUs in closedloop applications could lead to power system instability. Although the use of virtual private network (VPN) tunnels eliminates many security vulnerabilities, VPNs are still vulnerable to denial of service (DoS) attack that exploits a side-channel vulnerability. In this paper, the authors detail their analysis of DoS attack on a two-area four machine power system with a utility-scale photovoltaic (PV) plant. Automatic generation control (AGC) is used to implement a tie-line bias control in one of the areas. The impact of PMU packet dropping on AGC operation and countermeasures are presented in this paper. Cellular computational network (CCN) prediction of PMU data is used to implement a virtual synchrophasor network (VSN). The data from VSN is used by the AGC when the PMU packets are disrupted by DoS attacks. Real-time experimental results show the CCN based VSN effectively inferred the missing data and mitigated the negative impacts of DoS attacks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ghiasi, M., Niknam, T., Wang, Z., Mehrandezh, M., Dehghani, M., & Ghadimi, N. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108975 · Cited by 494
Future challenges and mitigation methods for high photovoltaic penetration: A survey
Olowu, T. O., Sundararajan, A., Moghaddami, M., & Sarwat, A. I. (2018) · Energies · doi:10.3390/en11071782 · Cited by 167
Denial of service attack and defense method on load frequency control system
Li, Y., Zhang, P., & Ma, L. (2019) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2019.08.036 · Cited by 78
Secure Frequency Control of Hybrid Power System Under DoS Attacks via Lie Algebra
Cheng, Z., Yue, D., Shen, S., Hu, S., & Chen, L. (2022) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2022.3158550 · Cited by 54
Metadata
- Authors
- Zhong, X., Jayawardene, I., Venayagamoorthy, G. K., & Brooks, R.
- Venue
- IEEE Transactions on Emerging Topics in Computational Intelligence
- Published
- 2017-10
- Volume
- 1
- Issue
- 5
- Pages
- 375-390
- ISSN
- 2471-285X (ISSN-L)
- OpenAlex
- W2757303199
- Cited by
- 70
- References
- 0
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Denial of Service Attack on Tie-Line Bias Control in a Power System With PV Plant. https://app.cochat.ai/papers/10.1109/tetci.2017.2739838
- The paper
- Zhong, X., Jayawardene, I., Venayagamoorthy, G. K., & Brooks, R. (2017). Denial of Service Attack on Tie-Line Bias Control in a Power System With PV Plant. IEEE Transactions on Emerging Topics in Computational Intelligence. https://doi.org/10.1109/tetci.2017.2739838
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.