Brain–Machine Interface and Visual Compressive Sensing-Based Teleoperation Control of an Exoskeleton Robot
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a teleoperation control for an exoskeleton robotic system based on the brain-machine interface and vision feedback. Vision compressive sensing, brain-machine reference commands, and adaptive fuzzy controllers in joint-space have been effectively integrated to enable the robot performing manipulation tasks guided by human operator's mind. First, a visual-feedback link is implemented by a video captured by a camera, allowing him/her to visualize the manipulator's workspace and movements being executed. Then, the compressed images are used as feedback errors in a nonvector space for producing steady-state visual evoked potentials electroencephalography (EEG) signals, and it requires no prior information on features in contrast to the traditional visual servoing. The proposed EEG decoding algorithm generates control signals for the exoskeleton robot using features extracted from neural activity. Considering coupled dynamics and actuator input constraints during the robot manipulation, a local adaptive fuzzy controller has been designed to drive the exoskeleton tracking the intended trajectories in human operator's mind and to provide a convenient way of dynamics compensation with minimal knowledge of the dynamics parameters of the exoskeleton robot. Extensive experiment studies employing three subjects have been performed to verify the validity of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Cited by
Implementation of a Brain-Computer Interface on a Lower-Limb Exoskeleton
Wang, C., Wu, X., Wang, Z., & Ma, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2853628 · Cited by 89
“At present, some studies combined the BCI with exoskeleton robot systems, to explore some applications [9]–[12].”
BackgroundInput Delay Estimation for Input-Affine Dynamical Systems Based on Taylor Expansion
Zhang, Y., Li, S., & Liao, L. (2021) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2020.3025136 · Cited by 10
Robust Human Movement Prediction by Completion-Generative Adversarial Networks with Huber Loss
Azari, M., Rafiei, H., & Akbarzadeh-T, M.-R. (2022) · 2022 29th National and 7th International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme57741.2022.10052859 · Cited by 4
Metadata
- Authors
- Qiu, S., Li, Z., He, W., Zhang, L., Yang, C., & Su, C.-Y.
- Venue
- IEEE Transactions on Fuzzy Systems
- Published
- 2017-02
- Volume
- 25
- Issue
- 1
- Pages
- 58-69
- ISSN
- 1063-6706 (ISSN-L)
- 1941-0034
- OpenAlex
- W2369439413
- Cited by
- 120
- References
- 2
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.