Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 223

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of the potential of hyperion for fire danger assessment by comparison to the airborne visible/infrared imaging spectrometer

Roberts, D.A., Dennison, P.E., Gardner, M.E., Hetzel, Y., Ustin, S.L., Lee, C.T. · 2003 · IEEE Transactions on Geoscience and Remote Sensing

Abstract

Parameters derived from remote sensing that can be used to assess fire danger include surface reflectance, live and dead biomass, canopy water content, species composition, and fuel state. Spectral bands and wavelength locations of traditional multispectral data make assessment of fire danger in Mediterranean shrublands difficult, although fire danger parameters have been derived from Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data. We compare nearly simultaneous acquisition of Hyperion and AVIRIS to evaluate spaceborne monitoring potential of fire danger in Southern California chaparral. Field spectra were acquired to support reflectance retrieval and construct a spectral library for vegetation mapping. Reflectance spectra retrieved from Hyperion and AVIRIS had similar shape and albedo, but SNR was five times higher in AVIRIS. Fuel condition was assessed using the endmember fractions from spectral mixture analysis, with both Hyperion and AVIRIS imaging spectrometer data providing similar fractions and spatial distributions. Hyperion demonstrated good capability for separating spectral signals from bare soil and dry plant litter. Canopy water content was compared using the 980- and 1200-nm liquid water bands, the water index, and the normalized difference water index. Results showed that Hyperion is capable of retrieving canopy water at 1200 nm, but demonstrates poor performance at 980 nm. Sensor noise and instrumental artifacts account for poor performance in this spectral region. Overall, full-spectrum measures outperformed band ratios because of a lower sensitivity to sensor noise in individual bands. Species and community mapping showed similar patterns with better accuracy for AVIRIS relative to Hyperion, but with both instruments achieving only 79% and 50% overall accuracy, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tgrs.2003.812904

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 223

Metadata

Authors
Roberts, D. A., Dennison, P. E., Gardner, M. E., Hetzel, Y., Ustin, S. L., & Lee, C. T.
Venue
IEEE Transactions on Geoscience and Remote Sensing
Published
2003-06
Volume
41
Issue
6
Pages
1297-1310
ISSN
0196-2892 (ISSN-L)
OpenAlex
W2015502627
Cited by
223
References
1
FWCI
8.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.