Condition monitoring of stator windings in induction motors. I. Experimental investigation of the effective negative-sequence impedance detector
The DOI matches its Crossref record.
Abstract
The former US Bureau of Mines funded a research project aimed at developing the enabling technology for incipient failure prediction in electric power system components as a means of reducing the injuries and fatalities that sometimes occur when equipment malfunctions. Over the ensuing years, interest in this has waxed and waned, but interest has been growing for both civilian and military applications. This paper addresses the level of turn-to-turn insulation deterioration that can be resolved using an online monitoring technique based upon an effective negative-sequence impedance detector. The detection of turn-to-turn defects is especially important because they are believed to represent the beginning stage of most motor winding failures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Metadata
- Authors
- Kohler, J. L., Sottile, J., & Trutt, F. C.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2002-09
- Volume
- 38
- Issue
- 5
- Pages
- 1447-1453
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2128098100
- Cited by
- 119
- References
- 0
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Condition monitoring of stator windings in induction motors. I. Experimental investigation of the effective negative-sequence impedance detector. https://app.cochat.ai/papers/10.1109/tia.2002.802935
- The paper
- Kohler, J. L., Sottile, J., & Trutt, F. C. (2002). Condition monitoring of stator windings in induction motors. I. Experimental investigation of the effective negative-sequence impedance detector. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2002.802935
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.