Sensorless rotor position estimation of an interior permanent-magnet motor from initial states
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes a torque, speed, or position control method at standstill and low speed in the interior permanent-magnet motor (IPMM) drive system without any rotational transducer. While IPMMs have originally magnetic saliency, it varies according to the load conditions and the control performance can be easily degraded. In this paper, the saliency or impedance difference is used as the conventional methods and, nevertheless, in order to amplify the difference containing the information of the rotor angle and to maintain a reasonable performance under any load condition a high-frequency injection scheme is proposed. A speed and position estimation scheme based on the characteristics of the high-frequency impedance is proposed. The scheme extracts the high-frequency impedance components related to the rotor position. An initial angle estimation scheme for starting from an arbitrary rotor position is also proposed. It can distinguish the north magnetic pole position from the south one in several decade milliseconds. The proposed scheme enables position control of a transducerless or position-sensorless IPMM. The experimental results clarify the satisfactory operation of the proposed position control algorithm under any load condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensorless control of AC machines at low speed and standstill based on the "INFORM" method
Schroedl, M. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557028 · Cited by 618 · cited 1×
“Some algorithms inject voltage signals in a sampling period to estimate rotor position [ 7 ], [8].”
Background
Cited by
Position Sensorless Permanent Magnet Synchronous Machine Drives—A Review
Wang, G., Valla, M., & Solsona, J. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2955409 · Cited by 855
Ichikawa, S., Tomita, M., Doki, S., & Okuma, S. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.870875 · Cited by 383
Analysis of permanent-magnet machine for sensorless control based on high-frequency signal injection
Jang, J.-H., Ha, J.-I., Ohto, M., Ide, K., & Sul, S.-K. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.836222 · Cited by 311
Self-citationJeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240
“In the case of low speed operation including starting, where the back EMF is too small to give the accurate rotor position, high-frequency injection methods in [10], [11] may be used.”
MethodSelf-citationBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Metadata
- Authors
- Ha, J.-I., Ide, K., Sawa, T., & Sul, S.-K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2003-05
- Volume
- 39
- Issue
- 3
- Pages
- 761-767
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2129353791
- Cited by
- 236
- References
- 1
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.