Abstract

The detection of noncatastrophic faults in conjunction with other factors can be used to determine the remaining life of an electric drive. As the frequency and severity of these faults increase, the working life of the drive decreases, leading to eventual failure. In this paper, methods are presented to identify developing electrical and mechanical faults based on both the short-time Fourier transform and wavelet analysis of the field-oriented currents in permanent-magnet ac drives. The different fault types are classified by developing a linear discriminant classifier based on the transform coefficients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tia.2007.900446

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 23

  1. 10.1016/0890-6955(95)00052-6 · DOI
  2. 10.1016/S0967-0661(01)00158-7 · DOI
  3. 10.1108/03321640310482931 · DOI
  4. 10.1109/IEMDC.2005.195697 · doi:10.1109/iemdc.2005.195697
  5. 10.1109/41.873209 · DOI · Paper page
  6. rajagopalan, 2005, wignerville distributions for detection of rotor faults in brushless dc (bldc) motors operating under non-stationary conditions, Proc Int Symp Diagnostics Electric Mach Power Electron and Drives, 313
  7. le roux, 2002, rotor fault analysis of a permanent magnet synchronous machine, Proc Int Conf Elect Mach
  8. 10.1109/PESC.1996.548786 · DOI
  9. cohen, 1995, TimeFrequency Analysis
  10. burrus, 1998, Introduction to Wavelets and Wavelet Transforms A Primer
  11. 10.1109/28.475698 · DOI · Paper page
  12. 10.1109/28.475697 · DOI · Paper page
  13. 10.1109/2943.485759 · DOI
  14. 10.1109/28.738983 · DOI
  15. 10.1109/TIA.2002.800591 · DOI · Paper page
  16. 10.1109/28.845047 · DOI · Paper page
  17. 10.1109/41.873210 · DOI · Paper page
  18. 10.1016/j.ymssp.2003.10.002 · DOI
  19. 10.1006/mssp.1997.0090 · DOI · Paper page
  20. mallat, 1999, A Wavelet Tour of Signal Processing
  21. young, 1974, Classification Estimation and Pattern Recognition
  22. dutilleux, 1987, an implementation of the algorithme trous to compute the wavelet transform, Proc Int Conf Wavelets Time-Freq Methods and Phase Space, 298
  23. krishnan, 2001, Electric Motor Drives Modeling Analysis and Control

Cited by

See all 145

Metadata

Authors
Zanardelli, W. G., Strangas, E. G., & Aviyente, S.
Venue
IEEE Transactions on Industry Applications
Published
2007
Volume
43
Issue
4
Pages
971-980
ISSN
0093-9994 (ISSN-L)
OpenAlex
W2167403880
Cited by
145
References
0
FWCI
14.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of Intermittent Electrical and Mechanical Faults in Permanent-Magnet AC Drives Based on Time–Frequency Analysis. https://app.cochat.ai/papers/10.1109/tia.2007.900446
The paper
Zanardelli, W. G., Strangas, E. G., & Aviyente, S. (2007). Identification of Intermittent Electrical and Mechanical Faults in Permanent-Magnet AC Drives Based on Time–Frequency Analysis. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2007.900446

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.