The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.
Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Abstract
Demagnetization fault is the most widespread fault in permanent magnet synchronous motors (PMSMs). Diagnosing this fault and extracting appropriate indexes for the PMSM are proposed and discussed in this paper. The index-extracting techniques and their advantages, disadvantages, and significant ambiguities are proposed, and it is emphasized how these ambiguities can be eliminated. This can help the newcomers to this field as well as designers and manufacturers of protection and fault diagnosis industry. In light of this information, the readers will have a full view on different aspects of each index. An optimum index can be chosen based on the sensitivity of application and the cost of index implementation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Partial demagnetization causes asymmetric and unbalanced radial forces, resulting in high vibration and noise.
“Partial demagnetization causes asymmetric and unbalanced radial forces, resulting in high vibration and noise [28].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [28]
Citations
Cites
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Transient analysis of cage induction machines under stator, rotor bar and end ring faults
Toliyat, H. A., & Lipo, T. A. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.391888 · Cited by 489
Design of Brushless Permanent-Magnet Machines
Hendershot, J. R., & Miller, T. J. E. (2010) · Medical Entomology and Zoology · Cited by 417
Kopp, N., Toliyat, H. A., & Kliman, G. B. (2010) · CRC Press eBooks · doi:10.1201/9781420030389 · Cited by 380
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243
Ruiz, J.-R. R., García, J. R., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
Lee, S. B., & Habetler, T. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811789 · Cited by 202
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
A Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151
Insulation failure prediction in AC machines using line-neutral voltages
Cash, M. A., Habetler, T. G., & Kliman, G. B. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.738983 · Cited by 149
Zanardelli, W. G., Strangas, E. G., & Aviyente, S. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900446 · Cited by 145
Automated Monitoring of Magnet Quality for Permanent-Magnet Synchronous Motors at Standstill
Hong, J., Hyun, D., Lee, S. B., Yoo, J.-Y., & Lee, K. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2049811 · Cited by 100
Delgado-Prieto, M., Espinosa, A. G., Ruiz, J.-R. R., Urresty, J.-C., & Ortega, J. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066538 · Cited by 96
Demagnetization Fault Diagnosis in Surface Mounted Permanent Magnet Synchronous Motors
Ebrahimi, B. M., & Faiz, J. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2217978 · Cited by 95
Self-citationBriz, F., Degner, M. W., García, P., & Díez, A. B. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.926773 · Cited by 94
Finite-Element Analysis of the Demagnetization of IPM-Type BLDC Motor With Stator Turn Fault
Lee, Y., Kim, K., & Hur, J. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2283498 · Cited by 76
Partial Demagnetization of Permanent Magnets in Electrical Machines Caused by an Inclined Field
Ruoho, S., & Arkkio, A. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.921951 · Cited by 76
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
Ishikawa, T., Seki, Y., & Kurita, N. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2243135 · Cited by 73
Bangura, J. F., Povinelli, R. J., Demerdash, N. A., & Brown, R. H. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.814582 · Cited by 71
Kim, K., Lee, Y., & Hur, J. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2311494 · Cited by 71
Shaft Trajectory Analysis in a Partially Demagnetized Permanent-Magnet Synchronous Motor
Urresty, J.-C., Atashkhooei, R., Riba, J., Romeral, L., & Royo, S. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2213565 · Cited by 62
Analytical Modeling Approach to Detect Magnet Defects in Permanent-Magnet Brushless Motors
Farooq, J. A., Djerdir, A., & Miraoui, A. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2001751 · Cited by 58
Riba, J., Espinosa, A. G., Romeral, L., & Cusidó, J. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.04.010 · Cited by 51
Detecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48
Bisschop, J. D., Abouelyazied, A., Sergeant, P., & Dupré, L. R. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2316851 · Cited by 47
Detection and estimation of demagnetization faults in permanent magnet synchronous motors
Chakraborty, S., Keller, E., Ray, A., & Mayer, J. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.11.005 · Cited by 37
Design features of low speed permanent magnet generator direct driven by wind turbine
Fengxiang, W., Jianlong, B., Qingming, H., & Pan, J. F. (2005) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2005.202699 · Cited by 27
Analysis on the direct-driven high power permanent magnet generator for wind turbine
Kim, K., Lim, S.-B., Jang, K.-B., Lee, S.-G., Lee, J. H., Son, Y.-G., Yeo, Y.-K., & Baek, S.-H. (2005) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2005.202521 · Cited by 22
Farooq, J. A., Djerdir, A., & Miraoui, A. (2009) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/03321640910999905 · Cited by 14
Stability tests of permanent magnets built with strontium ferrite
Glass, H. D., Brown, B. C., Foster, G. W., Fowler, W. B., Gustafson, R. W., Jackson, G. P., Ostiguy, J.-F., & Volk, J. (2002) · Particle Accelerator Conference (PAC) · doi:10.1109/pac.1997.753174 · Cited by 13
Signal processing of zero sequence voltage technique
Štulrajter, M., Vittek, J., Caruana, C., & Scelba, G. (2007) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417579 · Cited by 6
Flagged first, then by citations
1 of the 36 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- miller, 2002, Speed’s Electric Motors
Cited by
Sorted by citations
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The source of the PM temperature increase is the operation of the motor with a high load torque in difficult environmental conditions, but also damage to the stator winding in the form of ITSCs [15], [19], [20], [28]-[30], [32].”
BackgroundFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Self-citationHuang, F., Zhang, X., Qin, G., Xie, J., Peng, J., Huang, S., Long, Z., & Tang, Y. (2022) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2022.3165283 · Cited by 108
Skowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3146557 · Cited by 106
Fault Detection and Diagnosis of the Electric Motor Drive and Battery System of Electric Vehicles
Khaneghah, M. Z., Alzayed, M., & Chaoui, H. (2023) · Machines · doi:10.3390/machines11070713 · Cited by 102
Analysis and design of surface permanent magnet synchronous motor and generator
He, C., & Wu, T. X. (2019) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2019.00013 · Cited by 80
Ullah, Z., & Hur, J. (2018) · Energies · doi:10.3390/en11123309 · Cited by 72
Cheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 68
Krichen, M., Elbouchikhi, E., Hadj, N. B., Chaieb, M., Benbouzid, M., & Neji, R. (2020) · Machines · doi:10.3390/machines8030035 · Cited by 62
The Demagnetization Phenomenon in PM Machines: Principles, Modeling, and Design Considerations
Mahmouditabar, F., Vahedi, A., & Marignetti, F. (2023) · IEEE Access · doi:10.1109/access.2023.3274701 · Cited by 58
Zhao, J., Wang, L., Xu, L. H., Dong, F., Song, J., & Yang, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050360 · Cited by 56
Wind Turbine Failures Review and Trends
Santelo, T. N., de Oliveira, C. M. R., Maciel, C. D., & Monteiro, J. R. B. D. A. (2021) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-021-00789-8 · Cited by 56
A Novel Method for Diagnosing Demagnetization Fault in PMSM Using Toroidal-Yoke-Type Search Coil
Chen, H., Gao, C., Si, J., Nie, Y., & Hu, Y. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3134991 · Cited by 56
A New Demagnetization Fault Recognition and Classification Method for DPMSLM
Song, J., Zhao, J., Dong, F., Zhao, J., Xu, L. H., & Yao, Z. Q. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2928008 · Cited by 55
Gyftakis, K. N., Rasid, S. A., Skarmoutsos, G. A., & Mueller, M. A. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3071598 · Cited by 48
Naderi, P. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0403 · Cited by 48
Song, J., Zhao, J., Zhang, X., Dong, F., Zhao, J., Xu, L. H., & Yao, Z. Q. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2962730 · Cited by 41
Ehya, H., Nysveen, A., & Skreien, T. N. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3078136 · Cited by 41
Zhang, S., Liang, W., Zhao, W., Luan, Z., Wang, C., & Xu, K. (2024) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2024.111644 · Cited by 38
Usman, A., & Rajpurohit, B. S. (2019) · IEEE Access · doi:10.1109/access.2019.2946694 · Cited by 34
An improved equivalent-input-disturbance approach for PMSM drive with demagnetization fault
Huang, G., Li, J., Fukushima, E. F., Zhang, C., He, J., & Zhao, K. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.06.010 · Cited by 34
Eccentricity fault diagnosis indices for permanent magnet machines: state‐of‐the‐art
Faiz, J., & Nejadi-Koti, H. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5751 · Cited by 33
Self-citationFinite Element Modeling of Demagnetization Fault in Permanent Magnet Direct Current Motors
Khan, M. S., Okonkwo, U. V., Usman, A., & Rajpurohit, B. S. (2018) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2018.8586622 · Cited by 31
Usman, A., & Rajpurohit, B. S. (2020) · IEEE Access · doi:10.1109/access.2020.3005038 · Cited by 30
Ishikawa, T., & Igarashi, N. (2019) · Applied Sciences · doi:10.3390/app9153111 · Cited by 26
Zhang, J., Tounzi, A., Bénabou, A., & Menach, Y. L. (2020) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2020.02.009 · Cited by 25
Nejadi-Koti, H., Faiz, J., & Demerdash, N. A. O. (2017) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2017.8002299 · Cited by 24
Self-citationSong, J., Zhao, J., Dong, F., Zhao, J., & Song, X. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2961175 · Cited by 23
Gao, J., Gui, W., Yang, C., Peng, T., Luo, J., & Han, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3265969 · Cited by 23
Qin, Y., Li, G., Jia, C., & Mckeever, P. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3229357 · Cited by 22
Demagnetization Fault Diagnosis of a PMSM for Electric Drilling Tools Using GAF and CNN
Zhang, Q., Cui, J., Xiao, W., Mei, L., & Yu, X. (2024) · Electronics · doi:10.3390/electronics13010189 · Cited by 20
Faiz, J., Nejadi-Koti, H., & Exiri, A. H. (2017) · Electric Power Components and Systems · doi:10.1080/15325008.2017.1293196 · Cited by 20
Self-citationRotor fault diagnosis in permanent magnet synchronous machine using the midpoint voltage of windings
Bossio, J. M., Ruschetti, C. R., Bossio, G. R., Verucchi, C., & Angelo, C. H. D. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0428 · Cited by 20
Gritli, Y., Tani, A., Rossi, C., & Casadei, D. (2018) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2018.06.002 · Cited by 19
Pasqualotto, D., & Zigliotto, M. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12059 · Cited by 19
Overview of Diagnostic Methods for Rotating Electrical Machines
Djagarov, N. F., Enchev, G., Grozdev, Z., & Djagarova, J. (2020) · International Conference on Energy Efficiency and Agricultural Engineering (EE&AE) · doi:10.1109/eeae49144.2020.9279018 · Cited by 18
Study of a Combined Demagnetization and Eccentricity Fault in an AFPM Synchronous Generator
Barmpatza, A. C., & Kappatou, J. C. (2020) · Energies · doi:10.3390/en13215609 · Cited by 17
Zhan, H., Wu, L., Lyu, Z., Du, Y., & Fang, Y. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3217401 · Cited by 16
Gliga, L. I., Chafouk, H., Popescu, D., & Lupu, C. (2018) · International Conference on Systems and Control (ICSC) · doi:10.1109/icosc.2018.8587632 · Cited by 16
Bisschop, J. D., Abdallh, A. M. A., Sergeant, P., & Dupré, L. R. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0568 · Cited by 16
Model-Based Luenberger State Observer for Detecting Interturn Short Circuits in PM Machines
Qin, Y., Li, G., Zhu, Z. Q., Foster, M. P., Stone, D. A., Jia, C. J., & Mckeever, P. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3478840 · Cited by 15
A data-driven intelligent fault diagnosis framework for permanent magnet in PMSM
Wang, H., Wang, L., Wu, Q., Pei, H., & Diao, L. (2024) · Alexandria Engineering Journal · doi:10.1016/j.aej.2024.11.030 · Cited by 15
Chen, Z., Li, Z., & Ma, H. (2016) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-160056 · Cited by 15
Zhang, X., Liang, W., Qu, Y., Wang, X., & Huang, S. H. (2023) · IEEE Transactions on Reliability · doi:10.1109/tr.2023.3339331 · Cited by 14
Investigation of Inter-Turn Short-Circuit Fault of PM Machines Using PWM Voltage-Based Modeling
Qin, Y., Li, G., Jia, C., & Mckeever, P. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3277209 · Cited by 14
Diagnosis and discernment between eccentricity and demagnetization faults in PMSM drives
Koura, M. B., Boudinar, A. H., Aimer, A. F., Bendiabdellah, A., & Gherabi, Z. (2021) · Journal of Power Electronics · doi:10.1007/s43236-020-00204-6 · Cited by 14
Ngo, D., Hsieh, M., & Le, T. D. (2020) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2020.3023176 · Cited by 13
Hsieh, M., Ngo, D., & Thao, N. G. M. (2022) · Electronics · doi:10.3390/electronics11030397 · Cited by 13
Analytical Modeling and Analysis of Permanent-Magnet Motor with Demagnetization Fault
Shi, C., Peng, L., Zhang, Z., & Shi, T. (2022) · Sensors · doi:10.3390/s22239440 · Cited by 13
Demagnetization faults detection in an axial flux permanent magnet synchronous generator
Barmpatza, A. C., & Kappatou, J. C. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062349 · Cited by 12
Usman, A., Joshi, B. M., & Rajpurohit, B. S. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8926825 · Cited by 12
EWT Implementation for Examining Demagnetization Fault in PMSM using FEM *
Praveen Kumar, N., & Balakrishnan, P. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080132 · Cited by 11
Fan, D., Zhu, X., Quan, L., & Xiang, Z. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.0002 · Cited by 11
Irreversible demagnetization analysis of RWAFPM motor using modified MEC algorithm
Mahmouditabar, F., Vahedi, A., Ojaghlu, P., & Takorabet, N. (2020) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-01-2020-0021 · Cited by 11
Condition monitoring of rotating electrical machines
Sarma, N., Tuohy, P. M., & Djurović, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821204-2.00136-7 · Cited by 11
Disambiguation of Uniform Demagnetization Fault From Position Sensor Fault in FOC PMSM Applications
Kuruppu, S. S., & Abeyratne, S. G. (2022) · IEEE Access · doi:10.1109/access.2022.3210178 · Cited by 9
Usman, A., & Rajpurohit, B. S. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070363 · Cited by 9
Gao, J., Gui, W., Yang, C., Peng, T., Yang, Y. P., Luo, J., & Yang, C. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3396466 · Cited by 8
Yu, Y., Yuan, C. X., Zeng, D., Carbone, G., Hu, Y.-M., & Yang, J. (2024) · Actuators · doi:10.3390/act13120511 · Cited by 8
Shao, P., Tang, X., Zheng, B., Li, D., Chen, S., & Lin, H. (2023) · Sustainability · doi:10.3390/su15021239 · Cited by 8
Characteristic Analysis of Partial Demagnetization Faults in Surface Mounted BLDC Motors
Usman, A., & Rajpurohit, B. S. (2020) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias44978.2020.9334844 · Cited by 8
Garcia-Calva, T. A., Gyftakis, K. N., Skarmoutsos, G. A., Mueller, M. A., Moríñigo-Sotelo, D., & Romero-Troncoso, R. D. J. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3312362 · Cited by 8
Zhu, X., Hu, Y., Yu, Y., Zeng, D., Yang, J., & Carbone, G. (2024) · Scientific Reports · doi:10.1038/s41598-024-77225-9 · Cited by 7
Gritli, Y., Rossi, C., Pilati, A., Tani, A., & Casadei, D. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3542901 · Cited by 7
Hou, Z., Huang, J., Liu, H., Liu, Z., Ye, M., & Yang, J. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0625 · Cited by 7
Zarate, S., Almandoz, G., Ugalde, G., Poza, J., & Escalada, A. J. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506755 · Cited by 7
Fault Diagnosis of BLDC Motor Drive using Vibration Spectrum Analysis: Part II
Sharma, V. K., Usman, A., & Rajpurohit, B. S. (2020) · IEEE International Power and Renewable Energy Conference (IPRECON) · doi:10.1109/iprecon49514.2020.9315236 · Cited by 7
Demagnetisation fault detection in PMSM using zero sequence current components
Ding, S., Hang, J., Li, H., & Wang, Q. (2017) · Electronics Letters · doi:10.1049/el.2016.2600 · Cited by 6
Ding, S., He, W. Y., & Hang, J. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3515114 · Cited by 6
Gao, J., Gui, W., Yang, C., Tao, H., & Peng, T. (2021) · CAA Symposium on Fault Detection, Supervision and Safety for Technical Processes (SAFEPROCESS) · doi:10.1109/safeprocess52771.2021.9693669 · Cited by 6
Song, J., Li, F., Zhao, J., Wang, L., Liu, B., Wang, X., & Lu, S. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3590405 · Cited by 5
Chen, Z., Liang, Z., Liang, D., & Jia, S. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3505255 · Cited by 5
Rasid, S. A., Gyftakis, K. N., & Mueller, M. A. (2023) · Energies · doi:10.3390/en16062767 · Cited by 5
Chen, C., Lin, C.-J., Yang, F.-J., & Lin, F. (2024) · Applied Sciences · doi:10.3390/app14209570 · Cited by 5
A method to estimate the process noise covariance for a certain class of nonlinear systems
Gliga, L. I., Chafouk, H., Popescu, D., & Lupu, C. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.05.054 · Cited by 5
Usman, A., & Rajpurohit, B. S. (2020) · IEEE Texas Power and Energy Conference (TPEC) · doi:10.1109/tpec48276.2020.9042583 · Cited by 5
Abdolmaleki, M., Asef, P., & Vagg, C. (2024) · Magnetism · doi:10.3390/magnetism4040023 · Cited by 4
Rostami, M., Naderi, P., & Shiri, A. (2021) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-06-2021-0201 · Cited by 4
Usman, A., & Rajpurohit, B. S. (2022) · Energy Conversion and Economics · doi:10.1049/enc2.12054 · Cited by 4
Gao, J., Gui, W., Yang, C., Peng, T., Luo, J., & Yang, C. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131663 · Cited by 4
Demagnetization Diagnosing in PMSM Based on SIDDTW Under Nonstationary Conditions
Peng, X., Peng, T., Chen, Z., Yang, C., & Tao, H. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255119 · Cited by 4
Usman, A., Rajpurohit, B. S., Sharma, V. K., Divakar, B. P., & Agamloh, E. B. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605564 · Cited by 4
Comprehensive Study on Various Types of Magnets Used in Permanent Magnet Electrical Motors
Ranjan, P., & Kalla, U. K. (2024) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp61132.2024.10752109 · Cited by 3
Usman, A., Sharma, V. K., & Rajpurohit, B. S. (2021) · IET Energy Systems Integration · doi:10.1049/esi2.12024 · Cited by 3
Garcia-Calva, T. A., Gyftakis, K. N., Skarmoutsos, G. A., Mueller, M. A., Moríñigo-Sotelo, D., & Romero-Troncoso, R. D. J. (2022) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem51905.2022.9910737 · Cited by 3
Demagnetization Analysis and Optimization of Bonded Nd-Fe-B Magnet Rings in Brushless DC Motors
Wang, Y., Zhan, H., Gong, Y., Wang, M., Yu, J., Zhang, Z., Yang, Y., & Wang, L. (2025) · Machines · doi:10.3390/machines13020075 · Cited by 3
Gherabi, Z., Benouzza, N., Bendiabdellah, A., & Toumi, D. (2021) · Periodica Polytechnica Electrical Engineering and Computer Science · doi:10.3311/ppee.16423 · Cited by 2
Effect of demagnetization faults on line start AF-PMSM performance
Eker, M., & Özsoy, M. K. (2022) · Journal of Power Electronics · doi:10.1007/s43236-022-00439-5 · Cited by 2
Chen, C., Wu, Y.-C., Lin, C.-J., & Lin, F. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3604134 · Cited by 2
Gritli, Y., Tani, A., Rossi, C., & Casadei, D. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062348 · Cited by 2
MCSA versus Flux Monitoring for Demagnetization Diagnosis in Axial-Flux PM Generators
Skarmoutsos, G. A., Gyftakis, K. N., & Mueller, M. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605530 · Cited by 2
Demagnetization effects of surface-mounted permanent magnet synchronous wind generator
Dalcalı, A., & Kurt, E. (2024) · Journal of Energy Systems · doi:10.30521/jes.1362581 · Cited by 2
Design of High Efficiency Brushless Permanent Magnet Machines and Driver System
He, C. (2018) · Journal of International Crisis and Risk Communication Research · Cited by 2
Zhang, S., Li, S., He, L., Restrepo, J. A., & Habetler, T. G. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.02116 · Cited by 2
Faiz, J., Nejadi-Koti, H., & Keravand, M. (2017) · International Aegean Conference on Electrical Machines and Power Electronics & International Conference on Optimization of Electrical and Electronic Equipment (ACEMP-OPTIM) · doi:10.1109/optim.2017.7975005 · Cited by 1
Self-citationInitial Design of Free energy magnetic generator (FEMG)
Mostaman, N. A., Sulaıman, E., Jenal, M., & Somroo, I. A. (2023) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1261/1/012005 · Cited by 1
Demagnetization Fault Analysis of FSCW-PMM with Four-Layer Star-Delta Winding
Chen, Z., Fan, C., Wan, X., Ling, Z., & Wang, F. (2023) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems59686.2023.10344580 · Cited by 1
Usman, A., & Rajpurohit, B. S. (2023) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias54024.2023.10406969 · Cited by 1
Birasa, R., Ruiz-Sarrió, J. E., Idris, D. K. M., Daviu, J. A. A., & Martis, C. S. (2024) · International Conference and Exposition on Electrical and Power Engineering (EPE) · doi:10.1109/epei63510.2024.10758186 · Cited by 1
Koutrakos, K., Lamprokostopoulos, A., & Mitronikas, E. D. (2025) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped53223.2025.11154266 · Cited by 1
Metadata
- Authors
- Faiz, J., & Nejadi-Koti, H.
- Affiliations
- University of Tehran (IR)
- Venue
- IEEE Transactions on Magnetics
- Published
- 2016-04
- Volume
- 52
- Issue
- 4
- Pages
- 1-11
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2307389737
- Cited by
- 119
- References
- 36
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 16 · 2023: 14 · 2022: 14 · 2021: 16 · 2020: 17 · 2019: 11 · 2018: 9 · 2017: 6 · 2016: 3
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, demagnetization fault, fault diagnosis, fault index, fault sensitivity, motor protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review