Improve the Stability and the Accuracy of Power Hardware-in-the-Loop Simulation by Selecting Appropriate Interface Algorithms
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The closed-loop stability and the simulation accuracy are two paramount issues in power hardware-in-the-loop (HIL) simulation in regard to the operational safety and the experiment reliability. In this paper, the stability issue of the power HIL simulation is first introduced with a simple example. A stability analysis and accuracy estimation method based on the system's loop transfer function is later given. Five different interface algorithms are described, and their respective characteristics with respect to the system stability are compared. Through Matlab simulations and field experiments of two representative power HIL examples, it is revealed that certain interface algorithms exhibit higher stability and accuracy than the others under the given conditions. A recommendation for selecting appropriate interface algorith.ms is finally proposed at the end of this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Cited by
Microgrid Stability Definitions, Analysis, and Examples
Farrokhabadi, M., Canizares, C. A., Simpson-Porco, J. W., Nasr, E., Fan, L., Mendoza-Araya, P. A., Tonkoski, R., Tamrakar, U., Hatziargyriou, N., Lagos, D., et al. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2925703 · Cited by 752
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Characteristics and Design of Power Hardware-in-the-Loop Simulations for Electrical Power Systems
Lauss, G., Faruque, M. O., Schoder, K., Dufour, C., Viehweider, A., & Langston, J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2464308 · Cited by 308
A Megawatt-Scale Power Hardware-in-the-Loop Simulation Setup for Motor Drives
Steurer, M., Edrington, C. S., Sloderbeck, M., Ren, W., & Langston, J. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036639 · Cited by 213
Self-citationJayawardana, I., Ho, C. N. M., & Zhang, Y. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3093303 · Cited by 35
“Several IAs are presented in the literature, including the ideal transformer method (ITM), the transmission line model (TLM), the partial circuit duplication (PCD) and the damping impedance method (DIM) and, their performance is analyzed extensively in [11], [29]-[31].”
MethodEvaluation of Virtual Inertia Control Strategies for MMC-based HVDC Terminals by P-HiL Experiments
D'Arco, S., Nguyen, T. T., & Suul, J. A. (2019) · IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2019.8927704 · Cited by 12
Metadata
- Authors
- Ren, W., Steurer, M., & Baldwin, T. L.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2008
- Volume
- 44
- Issue
- 4
- Pages
- 1286-1294
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2571551106
- Cited by
- 341
- References
- 1
- FWCI
- 19.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.