Stator Interturn Fault Detection of Synchronous Machines Using Field Current and Rotor Search-Coil Voltage Signature Analysis
The DOI matches its Crossref record.
Abstract
Our recent observations suggested that harmonics in the field current are very promising to detect stator interturn faults in synchronous machines. So far, an increase in some of the even harmonics in the field current has been reported to detect such faults. However, no explanation has been provided for the cause of these harmonics. Moreover, the even harmonics can significantly increase with supply unbalance as well as time harmonics, which can lead to a serious confusion. Hence, in this study, an in-depth investigation was conducted to determine the origin of various harmonic components in the field current and their feasibility to detect stator faults. It was found that, owing to structural asymmetries of the field winding, some of these components clearly increased with stator interturn fault. The findings are helpful to detect faults involving few turns without ambiguity, in spite of the presence of supply unbalance and time harmonics. Both simulation and experimental results are presented in this paper. The diagnosis results have also been verified using a rotor-mounted search coil, which can also be used to detect even a one-turn stator fault very effectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92
Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
“To monitor critical devices in real time, existing methods consist in either adding sensors [6], [7] or injecting appropriate signals [8].”
Method
Metadata
- Authors
- Neti, P., & Nandi, S.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 3
- Pages
- 911-920
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2171874489
- Cited by
- 103
- References
- 0
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stator Interturn Fault Detection of Synchronous Machines Using Field Current and Rotor Search-Coil Voltage Signature Analysis. https://app.cochat.ai/papers/10.1109/tia.2009.2018905
- The paper
- Neti, P., & Nandi, S. (2009). Stator Interturn Fault Detection of Synchronous Machines Using Field Current and Rotor Search-Coil Voltage Signature Analysis. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2009.2018905
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.