Application of Artificial Intelligence to Real-Time Fault Detection in Permanent-Magnet Synchronous Machines
The DOI matches its Crossref record.
Abstract
This paper discusses faults in rotating electrical machines in general and describes a fault detection technique using artificial neural network (ANN) which is an expert system to detect short-circuit fault currents in the stator windings of a permanent-magnet synchronous machine (PMSM). The experimental setup consists of PMSM coupled mechanically to a dc motor configured to run in torque mode. Particle swarm optimization is used to adjust the weights of the ANN. All simulations are carried out in MATLAB/SIMULINK environment. The technique is shown to be effective and can be applied to real-time fault detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 16
- stone, 2004, Electrical Insulation for Rotating Machines
- 10.1109/TEI.1981.298388 · doi:10.1109/tei.1981.298388
- 10.1109/TEI.1981.298388 · doi:10.1109/tei.1981.298388
- 10.1109/TEI.1981.298388 · doi:10.1109/tei.1981.298388
- 10.1109/PAPCON.1994.324477 · doi:10.1109/papcon.1994.324477
- 10.1109/MPER.1986.5528007 · doi:10.1109/mper.1986.5528007
- lui, 2008, Efforts on real-time implementation of PSO based PMSM parameter identification, Proc IEEE Power Energy Soc Gen Meet, 1
- 10.1109/TEC.2005.847975 · DOI · Paper page
- 10.1109/41.873207 · DOI · Paper page
- 10.1109/60.736315 · doi:10.1109/60.736315
- 10.1109/TIA.2004.834012 · DOI · Paper page
- su-hua, 2006, A parallel PSO approach to multi-objective reactive power optimization with static voltage stability consideration, IEEE/PES Transm Distrib Conf, 172, 10.1109/TDC.2006.1668478 · doi:10.1109/tdc.2006.1668478
- tsoukalas, 1997, Fuzzy and Neural Approaches in Engineering
- 10.1109/07IAS.2007.137 · doi:10.1109/07ias.2007.137
- 10.1109/41.491349 · doi:10.1109/41.491349
- 10.1109/ELINSL.2010.5549737 · doi:10.1109/elinsl.2010.5549737
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The MLP network is characterized by an extremely simple mathematical description, thanks to which it is used in the case of mechanical damages: bearing damage [121, 231], eccentricity [231], and in the case of the damage to the stator electrical circuits [215-218], [224], [225], [232], supply voltage unbalance [219],…”
MethodInfluentialChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Metadata
- Authors
- Nyanteh, Y., Edrington, C., Srivastava, S., & Cartes, D.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2013-05
- Volume
- 49
- Issue
- 3
- Pages
- 1205-1214
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W1985642765
- Cited by
- 95
- References
- 0
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Artificial Intelligence to Real-Time Fault Detection in Permanent-Magnet Synchronous Machines. https://app.cochat.ai/papers/10.1109/tia.2013.2253081
- The paper
- Nyanteh, Y., Edrington, C., Srivastava, S., & Cartes, D. (2013). Application of Artificial Intelligence to Real-Time Fault Detection in Permanent-Magnet Synchronous Machines. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2013.2253081
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.