The DOI matches its Crossref record.
Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems
Open accessAbstract
Pushed by the booming installations of single-phase photovoltaic (PV) systems, the grid demands regarding the integration of PV systems are expected to be modified. Hence, the future PV systems should become more active with functionalities of low-voltage ride through and grid support capability. The control methods, together with grid synchronization techniques, are responsible for the generation of appropriate reference signals in order to handle ride-through grid faults. Thus, it is necessary to evaluate the behaviors of grid synchronization methods and control possibilities in single-phase systems under grid faults. The intent of this paper is to present a benchmarking of grid fault modes that might come in future single-phase PV systems. In order to map future challenges, the relevant synchronization and control strategies are discussed. Some faulty modes are studied experimentally and provided at the end of this paper. It is concluded that there are extensive control possibilities in single-phase PV systems under grid faults. The second-order-general-integral-based phase-locked-loop technique might be the most promising candidate for future single-phase PV systems because of its fast adaptive-filtering characteristics and it is able to fulfill future standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters
Yang, Y., Blaabjerg, F., & Wang, H. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2282966 · Cited by 358
Self-citationYang, Y., Enjeti, P., Blaabjerg, F., & Wang, H. (2015) · IEEE Industry Applications Magazine · doi:10.1109/mias.2014.2345837 · Cited by 262
Self-citationYang, Y., Wang, H., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2346692 · Cited by 253
Self-citationPower electronics - the key technology for renewable energy system integration
Blaabjerg, F., Yang, Y., Ma, K., & Wang, X. (2015) · 2015 International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2015.7418680 · Cited by 148
Self-citation
Metadata
- Authors
- Yang, Y., Blaabjerg, F., & Zou, Z.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2013-09
- Volume
- 49
- Issue
- 5
- Pages
- 2167-2176
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2048719389
- Cited by
- 241
- References
- 0
- FWCI
- 24.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems. https://app.cochat.ai/papers/10.1109/tia.2013.2260512
- The paper
- Yang, Y., Blaabjerg, F., & Zou, Z. (2013). Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2013.2260512
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.