The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters
Open accessAbstract
Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV systems due to anti-islanding protection may contribute to grid disturbances. Thus, standards featuring with ancillary services for the next-generation PV systems are under a revision in some countries. The future PV systems have to provide a full range of services as what the conventional power plants do, e.g., low-voltage ride-through (LVRT) under grid faults and grid support service. In order to map future challenges, the LVRT capability of three mainstream single-phase transformerless PV inverters under grid faults is explored in this paper. Control strategies with reactive power injection are also discussed. The selected inverters are the full-bridge (FB) inverter with bipolar modulation, the FB inverter with dc bypass, and the Highly Efficient and Reliable Inverter Concept (HERIC). A 1-kW single-phase grid-connected PV system is analyzed to verify the discussions. The tests confirmed that, although the HERIC inverter is the best candidate in terms of efficiency, it is not very particularly feasible in case of a voltage sag. The other two topologies are capable of providing reactive current during LVRT. A benchmarking of those inverters is also provided in this paper, which offers the possibility to select appropriate devices and to further optimize the transformerless system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Self-citationA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621
Self-citationGrid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Self-citationToward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916
Self-citationYuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 815
Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
Self-citationTransformerless Inverter for Single-Phase Photovoltaic Systems
Gonzalez, R., Lopez, J., Sanchis, P., & Marroyo, L. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.892120 · Cited by 692
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Cited by
Power electronics - the key technology for renewable energy system integration
Blaabjerg, F., Yang, Y., Ma, K., & Wang, X. (2015) · 2015 International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2015.7418680 · Cited by 148
Self-citationDong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
Metadata
- Authors
- Yang, Y., Blaabjerg, F., & Wang, H.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2014-05
- Volume
- 50
- Issue
- 3
- Pages
- 1942-1952
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2158266110
- Cited by
- 358
- References
- 32
- FWCI
- 35.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters. https://app.cochat.ai/papers/10.1109/tia.2013.2282966
- The paper
- Yang, Y., Blaabjerg, F., & Wang, H. (2014). Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2013.2282966
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.