The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Control of a Hybrid AC/DC Microgrid Involving Energy Storage and Pulsed Loads
Abstract
This paper presents a real-time coordinated control of the hybrid ac/dc microgrids involving energy storage and pulsed loads. Grid-isolated hybrid microgrid applications require special considerations due to the intermittent generation, online energy storage control, and pulsed loads. In this study, we introduce a comprehensive frequency and voltage control scheme for a hybrid ac/dc microgrid consisting of a synchronous generator, solar generation emulator, and bidirectional (ac/dc and dc/dc) converters. A bidirectional controlled ac/dc converter with an active and reactive power decoupling technique is used to link the ac bus with the dc bus, while regulating the system voltage and frequency. A dc/dc boost converter with a maximum power point tracking function is implemented to maximize the intermittent energy generation from solar generators. Current-controlled bidirectional dc/dc converters are applied to connect each lithium-ion battery bank to the dc bus. Lithium-ion battery banks act as energy storage devices that serve to increase the system resiliency by absorbing or injecting power. Experimental results are presented for verification of the introduced hybrid ac/dc power flow control scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Cited by
Hybrid AC–DC Microgrid: Systematic Evaluation of Control Strategies
Gupta, A., Doolla, S., & Chatterjee, K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2727344 · Cited by 355
Shan, Y., Hu, J., Chan, K. W., Fu, Q., & Guerrero, J. M. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2873390 · Cited by 283
Metadata
- Authors
- Ma, T., Cintuglu, M. H., & Mohammed, O. A.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2017-01
- Volume
- 53
- Issue
- 1
- Pages
- 567-575
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2527418900
- Cited by
- 172
- References
- 1
- FWCI
- 17.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control of a Hybrid AC/DC Microgrid Involving Energy Storage and Pulsed Loads. https://app.cochat.ai/papers/10.1109/tia.2016.2613981
- The paper
- Ma, T., Cintuglu, M. H., & Mohammed, O. A. (2017). Control of a Hybrid AC/DC Microgrid Involving Energy Storage and Pulsed Loads. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2016.2613981
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.