Reactive Power Management for Overvoltage Prevention at High PV Penetration in a Low-Voltage Distribution System
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
A new approach for reactive power management with volt-var control, but considering inverters' capacity and sensitivity to the critical bus is presented in this paper. The approach addresses the voltage rise and reverse power flow issues when residential renewable energy sources such as rooftop solar panels produce more energy than the local load demand. The overvoltage is controlled by selective var injection based on the inverter location, capacity, and minimum power factor limit set by regulation. This method improves the voltage regulation of a distributed system with high penetration of renewable energy sources while efficiently utilizing the inverters' reactive power capacity. Simulation results are presented with a ten inverter network supplied by a 60 kVA distribution transformer. Experimental results are presented to validate the effectiveness of this method for overvoltage prevention of a distribution test system with three photovoltaic (PV) inverters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018 · cited 1×
“However, capacitor banks and tap changing transformers are not fast enough to compensate the voltage fluctuation due to transient events such as cloud passing over PV panels [8], [9].”
BackgroundCoordinated Active Power Curtailment of Grid Connected PV Inverters for Overvoltage Prevention
Tonkoski, R., Lopes, L. A. C., & El-Fouly, T. H. M. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2010.2098483 · Cited by 822 · cited 1×
“Analyzing the characteristics of power management in a shared network is also an important research topic [24], [25].”
BackgroundDemirok, E., González, P. C., Frederiksen, K. H. B., Sera, D., Rodriguez, P., & Teodorescu, R. (2011) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2011.2174821 · Cited by 530 · cited 4×
“2(c) combines the previous two methods to generate reactive power reference for the inverters [26].”
BackgroundMethodInfluentialAdaptive VAR Control for Distribution Circuits With Photovoltaic Generators
Yeh, H.-G., Gayme, D. F., & Low, S. H. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2183151 · Cited by 458 · cited 1×
“The capacitor banks add cost and their optimal placement is challenging and still a topic of research [3]–[5].”
BackgroundDistribution Network Capacity Assessment: Variable DG and Active Networks
Ochoa, L. F., Dent, C. J., & Harrison, G. P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2031223 · Cited by 400 · cited 1×
“The application of an online tap changing transformer has been discussed in [6] and [7].”
BackgroundInverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331
Voltage Support Provided by a Droop-Controlled Multifunctional Inverter
Vasquez, J. C., Mastromauro, R. A., Guerrero, J. M., & Liserre, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2015357 · Cited by 326 · cited 1×
“The most straightforward approach is to upgrade the existing distribution network by larger cables to reduce the impedances [1], [2].”
BackgroundAn Optimal and Distributed Method for Voltage Regulation in Power Distribution Systems
Zhang, B., Lam, A. Y. S., Dominguez-Garcia, A. D., & Tse, D. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2347281 · Cited by 325 · cited 1×
“Also, wireless communication for smart grid has been discussed in [30].”
BackgroundModel Predictive Control of Voltages in Active Distribution Networks
Valverde, G., & Van Cutsem, T. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2246199 · Cited by 309 · cited 1×
“Therefore, real power control is also an effective way to regulate the voltage in a distribution network [15]–[17].”
BackgroundSmart inverter volt/var control functions for high penetration of PV on distribution systems
Smith, J. W., Sunderman, W., Dugan, R., & Seal, B. (2011) · 2011 IEEE/PES Power Systems Conference and Exposition · doi:10.1109/psce.2011.5772598 · Cited by 301
Cited by
Voltage Optimization in PV-Rich Distribution Networks—A Review
Dubravac, M., Fekete, K., Topić, D., & Barukčić, M. (2022) · Applied Sciences · doi:10.3390/app122312426 · Cited by 26
Khan, H. A., & Rihan, M. (2023) · Computers and Electrical Engineering · doi:10.1016/j.compeleceng.2023.108872 · Cited by 14
Metadata
- Authors
- Safayet, A., Fajri, P., & Husain, I.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2017-11
- Volume
- 53
- Issue
- 6
- Pages
- 5786-5794
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2750270058
- Cited by
- 164
- References
- 30
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reactive Power Management for Overvoltage Prevention at High PV Penetration in a Low-Voltage Distribution System. https://app.cochat.ai/papers/10.1109/tia.2017.2741925
- The paper
- Safayet, A., Fajri, P., & Husain, I. (2017). Reactive Power Management for Overvoltage Prevention at High PV Penetration in a Low-Voltage Distribution System. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2017.2741925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.